用户名: 密码: 验证码:
Multicatheter interstitial brachytherapy versus intensity modulated external beam therapy for accelerated partial breast irradiation: A comparative treatment planning study with respect to dosimetry of organs at risk
详细信息    查看全文
文摘
To dosimetrically compare multicatheter interstitial brachytherapy (MIBT) and intensity modulated radiotherapy (IMRT) for accelerated partial breast irradiation (APBI) with special focus on dose to normal tissues and organs at risk (OAR-s).Material and methodsThirty-four patients with early stage breast cancer treated with MIBT were selected for the study. For each patient an additional IMRT treatment plan was created using the same CT data and contours as used in MIBT plans. OAR-s included ipsilateral non-target and contralateral breast, lung of both sides, skin, ribs and heart for left sided lesions. The CTV was created from the outlined lumpectomy cavity with a total margin (surgical + radiation) of 20 mm in six main directions. The PTV in IMRT plans was generated from CTV with an addition of isotropic 5 mm margin. The prescribed dose was 30.1 Gy with 7 × 4.3 Gy fractionation for both techniques. From dose-volume histograms quality parameters including volumes receiving a given dose (e.g. V100, V90, V50) and doses to specified volumes (e.g. D0.01 cm3, D0.1 cm3, D1 cm3) were calculated and compared.ResultsExcept for high dose, non-target breast received less dose with MIBT. V90 was 3.6% vs. 4.8% and V50 was 13.7% vs. 25.5% for MIBT and IMRT, respectively. Ipsilateral lung was spared better with MIBT. Mean lung dose was 5.1% vs. 7.1%, D1cm3 was 39.0% vs. 54.3% and V5 was 32.9% vs. 41.7% in favour of MIBT. For left sided lesions the heart was generally irradiated by larger doses with MIBT. Mean heart dose was 4.5% vs. 2.0% and D2cm3 was 18.3% vs. 19.7%, correspondingly. Volumetric maximal skin doses were similar, but regarding dose to 0.1 cm3 and 1 cm3 of most exposed volume MIBT provided significantly less doses (76.6% vs. 94.4% and 60.2% vs. 87.8%, respectively). Ribs received less dose with MIBT with values of 45.6% vs. 69.3% for D1cm3 and 1.4% vs. 4.2 cm3 for V50. Dose to contralateral breast and lung was low with both techniques. No significant differences were observed in maximal doses, but dose to volumes of 0.1 cm3 and 1 cm3 were less with MIBT for both organs. D1cm3 was 3.2% vs. 6.7% for breast and 3.7% vs. 5.6% for lung with MIBT and IMRT, respectively.ConclusionsThe target volume can be appropriately irradiated by both techniques, but MIBT generally spares normal tissues and organs at risk better than IMRT. Except for the heart, other critical structures receive less doses with brachytherapy. To observe whether these dosimetric findings translate into clinical outcome more studies are needed with assessment of toxicity profiles.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700