A microchannel heat exchanger with two heat sinks was designed for cooling CNG.
An extrapolation method for pressure drop gave significant computational savings.
Pin structures in the design provided even flow distribution into microchannels.
A symmetry method used for heat transfer greatly reduced the computational load.