用户名: 密码: 验证码:
Off pump repair of left ventricular rupture following mitral valve replacement: The crucial assistance of the IntraAortic Balloon Pump
详细信息    查看全文
文摘

INTRODUCTION

Left ventricular (LV) rupture is a not as frequent, but potentially lethal complication of mitral valve replacement or repair.

PRESENTATION OF CASE

We report a case of a 67-year-old man who underwent mitral valve replacement and Cox Maze IV procedure. A massive bleed from the LV rupture was noted postoperatively while the patient was extubated. The control of bleeding was impossible until an IntraAortic Balloon Pump (IABP) was inserted. A bovine pericardial patch was applied, overlapping an extensive epicardial area, perimetrically of the hematoma. Between the epicardium and the pericardial patch we applied an autologous fibrin sealant.

DISCUSSION

The off-pump technique used to repair the LV rupture after a MVR, is more feasible when the patient is supported by an IABP that subsequently decreases the tension of the myocardial suture site.

CONCLUSION

The IABP, is a necessary device, that decreases the tension along the suture site post a left ventricular rupture following a MVR.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700