Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler
详细信息    查看全文
文摘
High content of sulfur was detected in deposits. Sulfuric acid dew point corrosion was proved to be the root cause. Mechanisms were proposed to explain the perforation and distinct morphology on tubes. It was necessary to raise the operation temperature and control sulfur content.