用户名: 密码: 验证码:
Evaluation of the particle measurement programme (PMP) protocol to remove the vehicles' exhaust aerosol volatile phase
详细信息    查看全文
文摘
European regulation for Euro 5/6 light duty emissions introduced the measurement of non-volatile particles with diameter > 23 nm. The volatile phase is removed by using a heated dilution stage (150 °C) and a heated tube (at 300–400 °C). We investigated experimentally the removal efficiency for volatile species of the specific protocol by conducting measurements with two Euro 3 diesel light duty vehicles, a Euro 2 moped, and a Euro III heavy duty vehicle with the system's heaters on and off. The particle number distributions were measured with a Scanning Mobility Particle Sizer (SMPS) and a Fast Mobility Particle Sizer (FMPS). An Aerosol Mass Spectrometer (AMS) was used to identify the non-refractory chemical composition of the particles. A Multi-Angle Absorption Photometer (MAAP) was used to measure the black carbon concentration. The results showed that the condensed material in the accumulation mode (defined here as particles in the diameter range of  50–500 nm) was removed with an efficiency of 50–90 % . The (volatile) nucleation mode was also completely evaporated or was decreased to sizes < 23 nm; thus these particles wouldn't be counted from the particle counter, indicating the robustness of the protocol.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700