GJ steel is used in large projects like National Olympic Stadium and Canton Tower.
Eight doubly symmetric welded section beams were tested under a concentrated force.
Numerical simulations and parametric studies were carried out as well.
The results of tests and parametric studies were compared with different design codes.
Proper design methods for the overall stability of Q460GJ steel beams are recommended.