用户名: 密码: 验证码:
Thermo-hydraulic analysis on in-bed calorimetry in a thin double-layered annulus metal hydride bed
详细信息    查看全文
文摘
Korea has been developing the metal hydride beds for the ITER storage and delivery system (SDS). There are two major concerns for the bed: one is the rapid delivery/recovery rate according to the tokamak plasma operation scenarios, and the other is the accurate measurement of tritium inventory using in-bed calorimetry within limited time. One of the bed concepts considering now consists of the thin and double layers of ZrCo which are confined by the cylinder-shaped SUS filter and the primary vessel wall. The primary vessel wall is wound by the heating coils, and has the helium channels for the in-bed calorimetry. In this study, the three-dimensional thermo-hydraulic analysis is performed for the bed to investigate the in-bed calorimetry performance. Based on the transient simulation results with an assumption of complete removal of the decay heat by He-loop, it is found that the bed under pre-cooling condition satisfies the accountancy of ±1 g-T accuracy in 24 h and ±3 g-T accuracy in 8 h.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700