Design of a high energy neutron dosimeter using CR-39 with multi-layer radiator
详细信息    查看全文
文摘
Personal neutron dosimeters are necessary for radiation protection of nuclear workers in high energy accelerator facilities. To improve sensitivity for high energy neutrons above 10?MeV, a new personal neutron dosimeter was designed using a solid state nuclear track detector (CR-39) covered with Multi-Layer radiator consisting of polyethylene, polyamide and iron/aluminum sheets. In this work, we investigated various radiator combinations and thicknesses in order to detect high energy neutrons above 10?MeV. Energy response of each radiator was calculated using the multi-purpose Monte Carlo simulation code, Particle and Heavy Ion Transport System (PHITS). To evaluate the accuracy of our calculations, the energy response of each radiator was measured in a mono-energetic neutron field at the Facility of Radiation Standard (FRS) of the Japan Atomic Energy Agency (JAEA). The energy response of each radiator calculated by PHITS was in good agreement with our experimental results. The results obtained in this research indicate that PHITS is a useful software tool for the design of new personal neutron dosimeters using CR-39 and using Multi-layer radiator approach.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700