Evaporation of the Leidenfrost Droplet Located on a Thin Metal Foil
详细信息    查看全文
文摘
For the thin metal foil cooling that is not very intense, the temperature change in thickness can be neglected when the Biot number Bi<0.1. In this way the problem has been treated as unsteady and one-dimensional, and solved numerically using MATLAB computational software. The results are given for the thin cylindrical copper foil of the radius of R=25 mm and different thickness ranging from 0.2 to 2.0 mm.

In the case of the copper foil with a thickness h=0.2 mm at t=0.05 s, the temperature at the center decreases ∼3.3oC, while the rate of the temperature decrease is above 61.5 K/s and for higher foil thickness both values are significantly lower.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700