文摘
An absorption and desorption rig has been built at Telemark University College. The absorption column has a structured packing height of 1500 mm, a total height of 2500 mm and an inner diameter of 100 mm. The desorption column has a random packing height of 1000 mm and a total height (including a reboiler and a condenser) of 3000 mm. The rig also contains a rich/lean heat exchanger, a solvent cooler and two pumps. The purpose of the rig is to perform measurements of CO2 removal efficiency and energy consumption at different temperatures, flows and CO2 concentrations. Different solvents like carbonate solutions and amine mixtures can be studied. The CO2 absorption rig has been used successfully to measure the absorption efficiency as a function of different parameters at stable conditions. The measurements can be used to validate process calculations and to find optimum process conditions.