用户名: 密码: 验证码:
Molecular Hybrid Positron Emission Tomography/Computed Tomography Imaging of Cardiac Angiotensin II Type 1 Receptors
详细信息    查看全文
文摘
| Figures/TablesFigures/Tables | ReferencesReferences

Objectives

The goal of this study was to explore the feasibility of targeted imaging of the angiotensin II type 1 receptor (AT1R) in cardiac tissue, using clinical hybrid positron emission tomography/computed tomography (PET/CT).

Background

AT1R is an attractive imaging target due to its key role in various cardiac pathologies, including post-infarct left ventricular remodeling.

Methods

Using the novel AT1R ligand [11C]-KR31173, dynamic PET/CT was performed in young farm pigs under healthy conditions (n = 4) and 3 to 4 weeks after experimental myocardial infarction (n = 5). Ex vivo validation was carried out by immunohistochemistry and polymerase chain reaction. First-in-man application was performed in 4 healthy volunteers at baseline and under AT1R blocking.

Results

In healthy pigs, myocardial KR31173 retention was detectable, regionally homogeneous, and specific for AT1R, as confirmed by blocking experiments. Metabolism in plasma was low (85 ¡À 2 % of intact tracer after 60 min). After myocardial infarction, KR31173 retention, corrected for regional perfusion, revealed AT1R up-regulation in the infarct area relative to remote myocardium, whereas retention was elevated in both regions when compared with myocardium of healthy controls (8.7 ¡À 0.8 % and 7.1 ¡À 0.3 % /min vs. 5.8 ¡À 0.4 % /min for infarct and remote, respectively, vs. healthy controls; p < 0.01 each). Postmortem analysis confirmed AT1R up-regulation in remote and infarct tissue. First-in-man application was safe, and showed detectable and specific myocardial KR31173 retention, albeit at a lower level than pigs (left ventricular average retention: 1.2 ¡À 0.1 % /min vs. 4.4 ¡À 1.2 % /min for humans vs. pigs; p = 0.04).

Conclusions

Noninvasive imaging of cardiac AT1R expression is feasible using clinical PET/CT technology. Results provide a rationale for broader clinical testing of AT1R-targeted molecular imaging.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700