Comparison of methods for the assessment of locomotor activity in rodent safety pharmacology studies
详细信息    查看全文
文摘

Introduction

General neurobehavioral assays, like a modified Irwin test or a functional observational battery, are necessary for central nervous system (CNS) safety pharmacology testing near the end of the target validation (early discovery) stage of preclinical drug development. However, at earlier stages, when a greater number of test compounds must be screened for potential CNS side effects, locomotor activity assessment may be a better tool for the comparison of compounds.

Methods

Spontaneous locomotor activity counts obtained from two automated test systems – an infrared beam-based activity meter (Actimeter) and the mechanical vibration-based LABORAS – were compared in rats dosed with chlorpromazine (2–8 mg/kg) or caffeine (3–24 mg/kg), p.o. A modified Irwin test was also performed to visually observe the neurobehavioral effects.

Results

In all three assays, dose-dependent sedation- and excitation-related effects were observed with chlorpromazine and caffeine, respectively. The two automated activity-detection systems exhibited similar sensitivities in determining changes in locomotor activity, but with the LABORAS being more sensitive than the Actimeter in detecting caffeine-induced increases in vertical activity (rearing behavior).

Discussion

Infrared beam-based activity detection systems and LABORAS provide relatively-comparable quantitative data regarding locomotor activity. Practical considerations, such as relative cost versus degree of versatility, should be considered when deciding which system to use for the screening of test compounds during the earliest stages of preclinical drug development.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700