This study demonstrates the formation of a three-dimensional conducting framework through hybridization of bioelectrochemically active infinite coordination polymer (ICP) nanoparticles with single-walled carbon nanotubes (SWNTs) for highly sensitive and selective in vivo electrochemical monitoring with combination with in vivo microdialysis. The bioelectrochemically active ICP nanoparticles are synthesized through the self-assembly process of NAD+ and Tb3+, in which all biosensing elements including an electrocatalyst (i.e., methylene green, MG), cofactor (i.e., 尾-nicotinamide adenine dinucleotide, NAD+), and enzyme (i.e., glucose dehydrogenase, GDH) are adaptively encapsulated. The ICP/SWNT-based biosensors are simply prepared by drop-coating the as-formed ICP/SWNT nanocomposite onto a glassy carbon substrate. Electrochemical studies demonstrate that the simply prepared ICP/SWNT-based biosensors exhibit excellent biosensing properties with a higher sensitivity and stability than the ICP-based biosensors prepared only with ICP nanoparticles (i.e., without hybridization of SWNTs). By using a GDH-based electrochemical biosensor as an example, we demonstrate a technically simple yet effective online electroanalytical platform for continuously monitoring glucose in the brain of guinea pigs with the ICP/SWNT-based biosensor as an online detector in a continuous-flow system combined with in vivo microdialysis. Under the experimental conditions employed here, the dynamic linear range for glucose with the ICP/SWNT-biosensor is from 50 to 1000 渭M. Moreover, in vivo selectivity investigations with the biosensors prepared by the GDH-free ICPs reveal that ICP/SWNT-based biosensors are very selective for the measurement of glucose in the cerebral system. The basal level of glucose in the microdialysates from the striatum of guinea pigs is determined to be 0.31 卤 0.03 mM (n = 3). The study offers a simple route to the preparation of electrochemical biosensors, which is envisaged to be particularly useful for probing the chemical events involved in some physiological and pathological processes.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700