用户名: 密码: 验证码:
Evaluation of Atmospheric PCDD/F Depositions via Automated and Traditional Water Surface Samplers in Taiwan
详细信息    查看全文
  • 作者:Kai Hsien Chi ; Shuh Ji Kao ; Kung Ting Liu ; Tzu Yi Lee
  • 刊名:Environmental Science & Technology (ES&T)
  • 出版年:2012
  • 出版时间:March 6, 2012
  • 年:2012
  • 卷:46
  • 期:5
  • 页码:2839-2846
  • 全文大小:383K
  • 年卷期:v.46,no.5(March 6, 2012)
  • ISSN:1520-5851
文摘
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are a group of compounds of major environmental concern. Once emitted into the atmosphere, PCDD/Fs undergo photochemical reactions and enter other environmental compartments via wet and dry deposition. In this study, atmospheric PCDD/F depositions were collected via an automated PCDD/F deposition sampler and traditional cylindrical vessels, respectively, in northern, central, and southern Taiwan from 2008 to 2010. The automated PCDD/F precipitation sampler used in this study can prevent both resuspension and photodegradation of the PCDD/Fs collected and also effectively separates the PCDD/F samples into dry and wet contributions. The results indicate that the average atmospheric PCDD/F concentrations collected by the high-volume sampling trains were 13.6 卤 10 (n = 10), 15.6 卤 5.2 (n = 7), and 10.9 卤 6.3 (n = 6) fg I-TEQ/m3 in northern, central, and southern Taiwan, respectively. In addition, the results also indicate that the PCDD/F deposition flux collected with an automated PCDD/F sampler (1.84 卤 0.90鈥?.68 卤 5.1 pg I-TEQ/m2/day, n = 23) is significantly higher than that sampled with cylindrical vessels (1.11 卤 0.69鈥?.64 卤 5.2 pg I-TEQ/m2/day, n = 23). Based on the Mann鈥揥hitney statistical analysis, the p value (0.037) of PCDD/F deposition flux between those two samplers measurement is lower than 0.05. The difference is attributed to the fact that part of the PCDD/F depositions collected by traditional cylindrical vessels is photodegraded and revolatilized. In addition, the wet deposition flux of PCDD/Fs (3.66 to 470 pg I-TEQ/m2/rainy day, n = 23) observed in Taiwan is significantly higher than the dry deposition flux (0.38 to 4.55 pg I-TEQ/m2/sunny day, n = 23). The results demonstrate that the wet deposition is the major PCDD/F removal mechanism in the atmosphere. Furthermore, the overall PCDD/Fs deposition velocity and scavenging (rainout) coefficient in Taiwan are calculated as 0.20 卤 0.07 cm/s and 6.5 卤 0.2 脳 104, respectively.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700