用户名: 密码: 验证码:
Donor/acceptor nanoparticle pair-based singlet oxygen channeling homogenous chemiluminescence immunoassay for quantitative determination of bisphenol A
详细信息    查看全文
  • 作者:Changjiang Hou ; Lixia Zhao ; Fanglan Geng…
  • 关键词:Homogenous immunoassay ; Bisphenol A ; Chemiluminescence ; Oxygen channeling
  • 刊名:Analytical and Bioanalytical Chemistry
  • 出版年:2016
  • 出版时间:December 2016
  • 年:2016
  • 卷:408
  • 期:30
  • 页码:8795-8804
  • 全文大小:
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Analytical Chemistry; Biochemistry, general; Laboratory Medicine; Characterization and Evaluation of Materials; Food Science; Monitoring/Environmental Analysis;
  • 出版者:Springer Berlin Heidelberg
  • ISSN:1618-2650
  • 卷排序:408
文摘
Bisphenol A (BPA) is widely used in consumer products such as plastic bottles and food containers. It has become a ubiquitous environmental contaminant and poses a serious risk to human health. A rapid, sensitive, and high-throughput method for detecting BPA is therefore desirable. Herein, a donor/acceptor nanoparticle pair-based singlet oxygen channeling chemiluminescence homogenous immunoassay is developed for the determination of BPA. The donor nanoparticles were modified with phthalocyanine as a photosensitizer and were then coated with streptavidin. The acceptor nanoparticles were doped with thioxene derivatives and Eu(III) as a chemiluminescence emitter and then coated with anti-BPA antibody. Under light irradiation, oxygen near the donor surface transforms to singlet oxygen (1O2), which migrates to the acceptor and reacts with it, generating luminescence. Because 1O2 has a very short lifetime, luminescence is generated only when the donor and acceptor are in close proximity. This occurs when they are brought together by the antigen/antibody and streptavidin/biotin reaction. Based on this singlet oxygen channeling mechanism, a competitive homogenous chemiluminescence immunoassay for BPA was developed on 384 microplates. The assay exhibited linear detection over the range 10–1000 ng/mL and a limit of detection of 2.9 ng/mL. The intra- and inter-assay precisions were both below 5.1 %. The average recoveries of three spiked samples in tap and river water samples were in the range 95.5–121.0 %, in agreement with values obtained using high-performance liquid chromatography. The homogeneous assay is rapid, low cost, sensitive, and allows high-throughput, so is well suited for screening large numbers of environmental samples.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700