用户名: 密码: 验证码:
An efficient and accurate approach to MTE-MART for time-resolved tomographic PIV
详细信息    查看全文
  • 作者:K. P. Lynch ; F. Scarano
  • 刊名:Experiments in Fluids
  • 出版年:2015
  • 出版时间:March 2015
  • 年:2015
  • 卷:56
  • 期:3
  • 全文大小:4,986 KB
  • 参考文献:1. Adrian, RJ (1997) Dynamic ranges of velocity and spatial resolution of particle image velocimetry. Meas Sci Technol 8: pp. 1393-1398 CrossRef
    2. Adrian, RJ (2007) Hairpin vortex organization in wall turbulence. Phys Fluids 19: pp. 041301 CrossRef
    3. Atkinson, C, Soria, J (2009) An efficient simultaneous reconstruction technique for tomographic particle image velocimetry. Exp Fluids 47: pp. 553-568 CrossRef
    4. Atkinson C, Buchmann N, Stanislas M, Soria J (2010) Adaptive MLOS-SMART improved accuracy tomographic PIV. In: 15th international symposium on application of laser techniques to fluid mechanics. Lisbon, Portugal
    5. Bernardini, M, Pirozzoli, S (2011) Wall pressure fluctuations beneath supersonic turbulent boundary layers. Phys Fluids 23: pp. 085102 CrossRef
    6. Silva, CM, Baidya, R, Marusic, I (2013) Enhancing Tomo-PIV reconstruction quality by reducing ghost particles. Meas Sci Technol 24: pp. 024010 CrossRef
    7. Discetti, S, Astarita, T (2012) Fast 3D PIV with direct sparse cross-correlations. Exp Fluids 52: pp. 765-777 CrossRef
    8. Discetti, S, Natale, A, Astarita, T (2013) Spatial filtering improved tomographic PIV. Exp Fluids 54: pp. 1505 CrossRef
    9. Elsinga, GE, Marusic, I (2010) Evolution and lifetimes of flow topology in a turbulent boundary layer. Phys Fluids 22: pp. 015102 CrossRef
    10. Elsinga, GE, Tokgoz, S (2014) Ghost hunting–an assessment of ghost particle detection and removal methods for tomographic PIV. Meas Sci Technol 25: pp. 084004 CrossRef
    11. Elsinga, GE, Scarano, F, Wieneke, B, Oudheusden, BW (2006) Tomographic particle image velocimetry. Exp Fluids 41: pp. 933-947 CrossRef
    12. Elsinga, GE, Westerweel, J, Scarano, F, Novara, M (2011) On the velocity of ghost particles and the bias errors in tomographic-PIV. Exp Fluids 50: pp. 825-838 CrossRef
    13. Elsinga, GE, Poelma, C, Schroder, A, Geisler, R, Scarano, F, Westerweel, J (2012) Tracking of vortices in a turbulent boundary layer. J Fluid Mech 697: pp. 273-295 CrossRef
    14. Ghaemi, S, Scarano, F (2010) Multi-pass light amplification for tomographic particle image velocimetry applications. Meas Sci Technol 21: pp. 127002 CrossRef
    15. Ghaemi, S, Scarano, F (2011) Counter-hairpin vortices in the turbulent wake of a sharp trailing edge. J Fluid Mech 689: pp. 317-356 CrossRef
    16. Huang, HT, Fielder, HF, Wang, JJ (1993) Limitation and improvement of PIV, part II. Particle image distortion, a novel technique. Exp Fluids 15: pp. 263-273 CrossRef
    17. Ianiro, A, Cardone, G (2012) Heat transfer rate and uniformity in multichannel swirling impinging jets. Appl Thermal Eng 49: pp. 89-98 CrossRef
    18. Keane, RD, Adrian, RJ (1990) Optimization of particle image velocimeters: Part 1: Double pulsed systems. Meas Sci Technol 1: pp. 1202-1215 CrossRef
    19. Lecordier B, Westerweel J (2004) The EUROPIV synthetic image generator (S.I.G.). In: Stanislas
  • 刊物类别:Engineering
  • 刊物主题:Engineering Fluid Dynamics
    Fluids
    Industrial Chemistry and Chemical Engineering
    Measurement Science and Instrumentation
    Thermodynamics
    Theoretical and Applied Mechanics
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-1114
文摘
The motion-tracking-enhanced MART (MTE-MART; Novara et al. in Meas Sci Technol 21:035401, 2010) has demonstrated the potential to increase the accuracy of tomographic PIV by the combined use of a short sequence of non-simultaneous recordings. A clear bottleneck of the MTE-MART technique has been its computational cost. For large datasets comprising time-resolved sequences, MTE-MART becomes unaffordable and has been barely applied even for the analysis of densely seeded tomographic PIV datasets. A novel implementation is proposed for tomographic PIV image sequences, which strongly reduces the computational burden of MTE-MART, possibly below that of regular MART. The method is a sequential algorithm that produces a time-marching estimation of the object intensity field based on an enhanced guess, which is built upon the object reconstructed at the previous time instant. As the method becomes effective after a number of snapshots (typically 5-0), the sequential MTE-MART (SMTE) is most suited for time-resolved sequences. The computational cost reduction due to SMTE simply stems from the fewer MART iterations required for each time instant. Moreover, the method yields superior reconstruction quality and higher velocity field measurement precision when compared with both MART and MTE-MART. The working principle is assessed in terms of computational effort, reconstruction quality and velocity field accuracy with both synthetic time-resolved tomographic images of a turbulent boundary layer and two experimental databases documented in the literature. The first is the time-resolved data of flow past an airfoil trailing edge used in the study of Novara and Scarano (Exp Fluids 52:1027-041, 2012); the second is a swirling jet in a water flow. In both cases, the effective elimination of ghost particles is demonstrated in number and intensity within a short temporal transient of 5-0 frames, depending on the seeding density. The increased value of the velocity space–time correlation coefficient demonstrates the increased velocity field accuracy of SMTE compared with MART.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700