用户名: 密码: 验证码:
Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm
详细信息    查看全文
  • 作者:Chao Wang ; Zhongbin Tian ; Jian Liu ; Linkai Jing ; Nikhil Paliwal…
  • 关键词:Intracranial aneurysm ; Stent ; Hemodynamics ; Velocity ; Wall shear stress ; Pressure
  • 刊名:Acta Neurochirurgica
  • 出版年:2016
  • 出版时间:April 2016
  • 年:2016
  • 卷:158
  • 期:4
  • 页码:811-819
  • 全文大小:1,108 KB
  • 参考文献:1.Augsburger L, Reymond P, Rufenacht DA, Stergiopulos N (2011) Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms. Ann Biomed Eng 39:850–863CrossRef PubMed
    2.Bernardini A, Larrabide I, Morales HG, Pennati G, Petrini L, Cito S, Frangi AF (2011) Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics. Interface Focus 1:338–348CrossRef PubMed PubMedCentral
    3.Bernardini A, Larrabide I, Petrini L, Pennati G, Flore E, Kim M, Frangi AF (2012) Deployment of self-expandable stents in aneurysmatic cerebral vessels: comparison of different computational approaches for interventional planning. Comp Methods Biomech Biomed Engin 15:303–311CrossRef
    4.Chalouhi N, Jabbour P, Gonzalez LF, Dumont AS, Rosenwasser R, Starke RM, Gordon D, Hann S, Tjoumakaris S (2012) Safety and efficacy of endovascular treatment of basilar tip aneurysms by coiling with and without stent assistance: a review of 235 cases. Neurosurgery 71:785–794CrossRef PubMed
    5.Clajus C, Sychra V, Strasilla C, Klisch J (2013) Stent-assisted coil embolization of intracranial aneurysms using the Solitaire AB Neurovascular Remodeling Device: initial and midterm follow-up results. Neuroradiology 55:629–638CrossRef PubMed
    6.Francis SE, Tu J, Qian Y, Avolio AP (2013) A combination of genetic, molecular and haemodynamic risk factors contributes to the formation, enlargement and rupture of brain aneurysms. J Clin Neurosci 20:912–918CrossRef PubMed
    7.Frosen J (2014) Smooth muscle cells and the formation, degeneration, and rupture of saccular intracranial aneurysm wall—a review of current pathophysiological knowledge. Transl Stroke Res 5:347–356CrossRef PubMed
    8.Frosen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A, Niemela M, Hernesniemi J (2012) Saccular intracranial aneurysm: pathology and mechanisms. Acta Neuropathol 123:773–786CrossRef PubMed
    9.Fu W, Gu Z, Meng X, Chu B, Qiao A (2010) Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model. J Biomech 43:1337–1342CrossRef PubMed
    10.Hong Y, Wang YJ, Deng Z, Wu Q, Zhang JM (2014) Stent-assisted coiling versus coiling in treatment of intracranial aneurysm: a systematic review and meta-analysis. PLoS One 9:e82311CrossRef PubMed PubMedCentral
    11.Kim M, Levy EI, Meng H, Hopkins LN (2007) Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm. Neurosurgery 61:1305–1312, discussion 1312–1303CrossRef PubMed PubMedCentral
    12.Kim M, Taulbee DB, Tremmel M, Meng H (2008) Comparison of two stents in modifying cerebral aneurysm hemodynamics. Ann Biomed Eng 36:726–741CrossRef PubMed PubMedCentral
    13.Kojima M, Irie K, Fukuda T, Arai F, Hirose Y, Negoro M (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165CrossRef PubMed PubMedCentral
    14.Kono K, Shintani A, Terada T (2014) Hemodynamic effects of stent struts versus straightening of vessels in stent-assisted coil embolization for sidewall cerebral aneurysms. PLoS One 9:e108033CrossRef PubMed PubMedCentral
    15.Krings T, Mandell DM, Kiehl TR, Geibprasert S, Tymianski M, Alvarez H, terBrugge KG, Hans FJ (2011) Intracranial aneurysms: from vessel wall pathology to therapeutic approach. Nat Rev Neurol 7:547–559CrossRef PubMed
    16.Larrabide I, Kim M, Augsburger L, Villa-Uriol MC, Rufenacht D, Frangi AF (2012) Fast virtual deployment of self-expandable stents: method and in vitro evaluation for intracranial aneurysmal stenting. Med Image Anal 16:721–730CrossRef PubMed
    17.Lawson MF, Newman WC, Chi YY, Mocco JD, Hoh BL (2011) Stent-associated flow remodeling causes further occlusion of incompletely coiled aneurysms. Neurosurgery 69:598–603, discussion 603–594CrossRef PubMed
    18.Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416, discussion E416CrossRef PubMed
    19.Meng H, Tutino VM, Xiang J, Siddiqui A (2014) High WSS or low WSS? Complex interactions of hemodynamics with intracranial aneurysm initiation, growth, and rupture: toward a unifying hypothesis. AJNR Am J Neuroradiol 35:1254–1262CrossRef PubMed
    20.Metaxa E, Tremmel M, Natarajan SK, Xiang J, Paluch RA, Mandelbaum M, Siddiqui AH, Kolega J, Mocco J, Meng H (2010) Characterization of critical hemodynamics contributing to aneurysmal remodeling at the basilar terminus in a rabbit model. Stroke 41:1774–1782CrossRef PubMed PubMedCentral
    21.Mut F, Aubry R, Lohner R, Cebral JR (2010) Fast numerical solutions of patient-specific blood flows in 3D arterial systems. Int J Numer Methods Biomed Eng 26:73–85CrossRef
    22.Paliwal N, Yu H, Damiano R, Xiang J, Yang X, Siddiqui A, Li H, Meng H (2014) Fast virtual stenting with vessel-specific initialization and collision detection. ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, American Society of Mechanical Engineers, Buffalo, NYCrossRef
    23.Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115CrossRef PubMed
    24.Rayz VL, Boussel L, Lawton MT, Acevedo-Bolton G, Ge L, Young WL, Higashida RT, Saloner D (2008) Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation. Ann Biomed Eng 36:1793–1804CrossRef PubMed PubMedCentral
    25.Shobayashi Y, Tateshima S, Kakizaki R, Sudo R, Tanishita K, Vinuela F (2013) Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. J Neurointerv Surg 5(Suppl 3):iii38–iii42CrossRef PubMed
    26.Spranger K, Ventikos Y (2014) Which spring is the best? Comparison of methods for virtual stenting. IEEE Trans Bio-Med Eng 61:1998–2010CrossRef
    27.Tanemura H, Ishida F, Miura Y, Umeda Y, Fukazawa K, Suzuki H, Sakaida H, Matsushima S, Shimosaka S, Taki W (2013) Changes in hemodynamics after placing intracranial stents. Neurol Med Chir 53:171–178CrossRef
    28.Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRef PubMed
  • 作者单位:Chao Wang (1)
    Zhongbin Tian (1)
    Jian Liu (1)
    Linkai Jing (1)
    Nikhil Paliwal (2) (3)
    Shengzhang Wang (4)
    Ying Zhang (1)
    Jianping Xiang (2) (3) (5)
    Adnan H. Siddiqui (2) (5) (6)
    Hui Meng (2) (3) (5)
    Xinjian Yang (1)

    1. Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tian Tan Hospital, Capital Medical University, TiantanXili 6, Dongcheng District, Beijing, China, 100050
    2. Toshiba Stroke and Vascular Research Center, University at Buffalo, The State University of New York, Buffalo, NY, USA
    3. Department of Mechanical and Aerospace Engineering, University at Buffalo, The State University of New York, Buffalo, NY, USA
    4. Department of Mechanics and Engineering Science, Fudan University, Shanghai, China
    5. Department of Neurosurgery, University at Buffalo, The State University of New York, Buffalo, NY, USA
    6. Department of Radiology, University at Buffalo, The State University of New York, Buffalo, NY, USA
  • 刊物主题:Neurosurgery; Interventional Radiology; Neuroradiology; Neurology; Surgical Orthopedics; Minimally Invasive Surgery;
  • 出版者:Springer Vienna
  • ISSN:0942-0940
文摘
Background Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700