用户名: 密码: 验证码:
Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty
详细信息    查看全文
  • 作者:Caroline Scemama ; Claudio Dora ; Jean Langlois…
  • 关键词:Highly cross ; linked polyethylene ; Total hip arthroplasty ; wear rates ; Martell Hip analysis
  • 刊名:International Orthopaedics
  • 出版年:2015
  • 出版时间:June 2015
  • 年:2015
  • 卷:39
  • 期:6
  • 页码:1051-1055
  • 全文大小:238 KB
  • 参考文献:1.Caton J, Prudhon JL (2011) Over 25 years survival after Charnley's total hip arthroplasty. Int Orthop 35:185-88PubMed Central PubMed View Article
    2.Harris WH, Muratoglu OK (2005) A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res 430:46-2
    3.Mu Z, Tian J, Wu T, Yang J, Pei F (2009) A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty. Int Orthop 33:599-04PubMed Central PubMed View Article
    4.Kuzyk PRT, Saccone M, Sprague S, Simunovic N, Bhandari M, Schemitsch EH (2011) Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials. J Bone Joint Surg Br 93(5):593-00
    5.Wannomae KK, Bhattacharyya S, Freiberg A, Estok D, Harris WH, Muratoglu O (2006) In vivo oxidation of retrieved cross-linked ultra–high-molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplast 21:1005-011View Article
    6.Martell J, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79(11):1635-641
    7.Martell JM, Berkson E, Berger R, Jacobs J (2003) Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 85-A(6):1111-117
    8.McCalden RW, Naudie DD, Yuan X, Bourne RB (2005) Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 87:2323-334PubMed View Article
    9.Meftah M, Klingenstein GG, Yun RJ, Ranawat AS, Ranawat CS (2013) Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis. J Bone Joint Surg 95:1193-197PubMed View Article
    10.Lee PCP, Shih CHC, Chen WJW, Tu YKY, Tai CLC (1999) Early polyethylene wear and osteolysis in cementless total hip arthroplasty: the influence of femoral head size and polyethylene thickness. J Arthroplasty 14:976-81PubMed View Article
    11.Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649-61PubMed View Article
    12.Bragdon CR, Martell JM, Greene ME, Estok II DM, Thanner J, K?rrholm J, Harris WH, Malchau H (2006) Comparison of femoral head penetration using RSA and the Martell method. Clin Orthop Relat Res 448:52-7
    13.Ranawat AS, Tsailis P, Meftah M, Koob TW, Rodriguez JA, Ranawat CS (2012) Minimum 5-year wear analysis of first-generation highly cross-linked polyethylene in patients 65 years and younger. J Arthroplast 27:354-57View Article
    14.Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop Relat Res 465:122-27PubMed
    15.Smith PN, Ling RS, Taylor R (1999) The influence of weight-bearing on the measurement of polyethylene wear in THA. J Bone Joint Surg Br 81:259-65PubMed View Article
    16.Bragdon CR, Thanner J, Greene ME, Malchau H, Digas G, Harris WH, K?rrholm J (2006) Standing versus supine radiographs in RSA evaluation of femoral head penetration. Clin Orthop Relat Res 448:46-1PubMed View Article
    17.Digas G, K?rrholm J, Thanner J, Herberts P (2007) 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop 78:746-54PubMed View Article
    18.Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A (2005) Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg Am 87:1816-821PubMed View Article
    19.Triclot P, Grosjean G, El Masri F, Courpied JP, Hamadouche M (2007) A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg Br 89-B:1439-445View Article
    20.Garcia-Rey E, Garcia-Cimbrelo E, Cruz-Pardos A, Ortega-Chamarro J (2008) New polyethylenes in total hip replacement: a prospective comparative clinical study of two types of liner. J Bone Joint Surg Br 90-B:149-53View Article
    21.McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD (2009) Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am 91:773-82PubMed View Article
    22.Thomas GER, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93:716-22PubMed View Article
    23.Bradford L, Baker DA, Graham J, Chawan A, Ries MD, Pruitt LA (2004) Wear and surface
  • 作者单位:Caroline Scemama (1)
    Claudio Dora (2)
    Jean Langlois (1)
    Moussa Hamadouche (1)

    1. Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, H?pital Cochin (AP-HP), Paris, France
    2. Department of Orthopaedic Surgery, Uniklinik Balgrist, Zürich, Switzerland
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Orthopedics
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-5195
文摘
Purpose Highly cross-linked polyethylenes (PE) have been developed with encouraging results in terms of wear. Another body of the literature has indicated potential catastrophic failures related to reduced fatigue properties and oxidation. Each PE available on the market has its own processing characteristics. The aim of this retrospective study was to evaluate the minimum five-year wear properties of an original highly cross-linked PE in a consecutive series of primary THAs. Methods Between August 2005 and December 2007, 80 patients with a mean age of 62.7?years were included. All patients had a 28-mm CoCr femoral head articulating with a highly cross-linked insert (Highcross?, Medacta SA) that was 100 Mrads gamma radiated, remelted at 150?°C, and ethylene oxide sterilized. The primary criterion for evaluation was the femoral head penetration, as measured by Hip Analysis Suite software. The steady state wear was also calculated. Functional results were evaluated according to the WOMAC score. Results Complete data were available for analysis in 67 patients at a mean follow-up of 5.5?years. The mean femoral head penetration was 0.128?±-.62?mm and the steady state wear was?.025?±-.22?mm/year. The WOMAC score significantly decreased from 16.5?±-.93 pre-operatively to 4.12?±-.5 at the latest follow-up (p <0.001). Conclusions The minimal five-year results of this retrospective study indicate that this particular highly cross-linked and remelted polyethylene had a low wear rate. Longer-term results are needed to warrant that these mid-term data will generate less osteolysis and resultant aseptic loosening.