用户名: 密码: 验证码:
Evaluation of the EDGE detector in small-field dosimetry
详细信息    查看全文
  • 作者:Hun-Joo Shin (11228)
    Myong-Ho Kim (11228)
    Ihl-Bohng Choi (11228)
    Young-nam Kang (21228)
    Dae-Hyun Kim (21228)
    Byung Ock Chio (21228)
    Hong Seok Jang (21228)
    Ji-Young Jung (31228)
    Seok Hyun Son (31228)
    Chul Seung Kay (31228)
  • 关键词:SRS ; IMRT ; Small ; field dosimetry ; EDGE detector ; Monte Carlo
  • 刊名:Journal of the Korean Physical Society
  • 出版年:2013
  • 出版时间:July 2013
  • 年:2013
  • 卷:63
  • 期:1
  • 页码:128-134
  • 全文大小:181KB
  • 参考文献:1. E. Pantelis / et al., Med. Phys. 39, 4875 (2012). CrossRef
    2. M. M. Aspradakis, J. P. Byrne, H. Palmans, K. Conway, K. Rosser, A. P. Warrington and S. Duane, / Small Field MV Photon Dosimetry, IPEM Report 103 (York, UK, 2010).
    3. I. J. Das, G. X. Ding and A. Ahnesjo, Med. Phys. 35, 206 (2008). CrossRef
    4. J. Fan, K. Paskalev, L. Wang, L. Jin, J. Li, A. Eldeeb and C. Ma, Med. Phys. 36, 5292 (2009). CrossRef
    5. P. Francescon, S. Cora, C. Cavedon, P. Scalchi, S. Reccanello and F. Colombo, Med. Phys. 25, 503 (1998). CrossRef
    6. M. Heydarian, P. W. Hoban and A. H. Beddoe, Phys. Med. Biol. 41, 93 (1996). CrossRef
    7. W. U. Laub and T. Wong, Med. Phys. 30, 341 (2003). CrossRef
    8. A. Moutsatsos / et al., Med. Phys. 36, 4277 (2009). CrossRef
    9. E. Pantelis, C. Antypas, L. Petrokokkinos, P. Karaiskos, P. Papagiannis, M. Kozicki, E. Georgiou, L. Sakelliou and I. Seimenis, Med. Phys. 35, 2312 (2008). CrossRef
    10. O. A. Sauer and J. Wilbert, Med. Phys. 34, 1983 (2007). CrossRef
    11. X. R. Zhu, J. J. Allen, J. Shi and W. E. Simon, Med. Phys. 27, 472 (2000). CrossRef
    12. M. Westermark, J. Arndt, B. Nilsson and A. Brahme, Phys. Med. Biol. 45, 685 (2000). CrossRef
    13. P. Francescon, S. Cora and C. Cavedon, Med. Phys. 35, 504 (2008). CrossRef
    14. P. Francescon, S. Cora, C. Cavedon and P. Scalchi, J. Appl. Clin. Med. Phys. 10, 2939 (2009).
    15. E. Pantelis, A. Moutsatsos, K. Zourari, W. Kilby, C. Antypas, P. Papagiannis, P. Karaiskos, E. Georgiou and L. Sakelliou, Med. Phys. 37, 2369 (2010). CrossRef
    16. H. Bouchard, J. Seuntjens, J. F. Carrier and I. Kawrakow, Med. Phys. 36, 4654 (2009). CrossRef
    17. H. Bouchard, J. Seuntjens and I. Kawrakow, Phys. Med. Biol. 56, 2617 (2011). CrossRef
    18. S. Dieterich and G. W. Sherouse, Med. Phys. 38, 4166 (2011). CrossRef
    19. G. X. Ding, Phys. Med. Biol. 48, 3865 (2003). CrossRef
    20. G. X. Ding, Med. Phys. 31, 2527 (2004). CrossRef
    21. R. Capote, F. Sanchez-Doblado, A. Leal, J. I. Lagares, R. Arrans and G. H. Hartmann, Med. Phys. 31, 2416 (2004). CrossRef
    22. F. Verhaegen, I. J. Das and H. Palmans, Phys. Med. Biol. 43, 2755 (1998). CrossRef
    23. D. W. Rogers, B. A. Faddegon, G. X. Ding, C. M. Ma, J. We and T. R. Mackie, Med. Phys. 22, 503 (1995). CrossRef
    24. D. Sheikh-Bagheri, D. W. Rogers, C. K. Ross and J. P. Seuntjens, Med. Phys. 27, 2256 (2000). CrossRef
    25. J. Jang, Y. N. Kang, D. O. Shin, B. O. Choi, T. K. Lee, I. B. Choi, M. C. Kim and S. I. Kwon, Korean J. Med. Phys. 17, 47 (2006).
  • 作者单位:Hun-Joo Shin (11228)
    Myong-Ho Kim (11228)
    Ihl-Bohng Choi (11228)
    Young-nam Kang (21228)
    Dae-Hyun Kim (21228)
    Byung Ock Chio (21228)
    Hong Seok Jang (21228)
    Ji-Young Jung (31228)
    Seok Hyun Son (31228)
    Chul Seung Kay (31228)

    11228. Catholic Comprehensive Hospital for Advanced Cancer, Incheon St. Mary’s Hospital, The Catholic University of Korea, Incheon, 403-720, Korea
    21228. Department of Radiation Oncology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, 135-701, Korea
    31228. Department of Radiation Oncology, Incheon St. Mary’s Hospital, The Catholic University of Korea, Incheon, 403-720, Korea
  • ISSN:1976-8524
文摘
This study evaluates a new diode detector design for small-field dosimetry. An accurate detector that has a small volume are necessary to compile data for stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), and intensity-modulated radiotherapy (IMRT). Two semiconductor diode detectors and one ionization chamber were used to measure the profiles, percent depth doses (PDDs), and relative output factors (OFs) of a Novalis 6-MV SRS beam. Profiles and PDD data were collected using 5.0-, 10.0-, 15.0-, 20.0-, 30.0-, and 50.0-mm micro multileaf collimators (mMLCs) at small fields and a 98.0 × 98.0-mm2 reference field. OFs were collected for each of the mMLCs. The EDGE diode detector, the diode detector, and the ion chamber (0.007 cc) were used in the study. Detector measurements were performed using the 3D water phantom with a source-to-surface distance of 100-cm at a depth of 1.5-cm. The measurements were analyzed using the IBA OmniPro Accept 7th version software. In addition, all data were compared to Monte Carlo simulations. The semiconductor diodes had similar OFs and PDDs for each of the mMLCs used. The Dmax values of the EDGE diode detector, measured from the PDD, ranged from 8.5 to 14.0-mm with an average of 12.4-mm. The field widths of the EDGE diode detector were found to have similar values. The performance of the EDGE diode detector was comparable for all small-field measurements. Additionally, no evidence of an energy response was observed for the EDGE detectors for a field of 98 × 98-mm2. This is particularly important when measuring the relative OF for small fields or gathering larger-sized field data for the commissioning of a treatment planning system.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700