用户名: 密码: 验证码:
Bulk evaluation and comparison of radiotherapy treatment plans for breast cancer
详细信息    查看全文
  • 作者:T. Kairn ; S. B. Crowe ; C. M. Langton…
  • 关键词:Treatment planning ; Data mining ; Radiation therapy
  • 刊名:Australasian Physical & Engineering Sciences in Medicine
  • 出版年:2016
  • 出版时间:September 2016
  • 年:2016
  • 卷:39
  • 期:3
  • 页码:633-644
  • 全文大小:991 KB
  • 刊物主题:Biomedicine general; Biophysics and Biological Physics; Medical and Radiation Physics; Biomedical Engineering;
  • 出版者:Springer Netherlands
  • ISSN:1879-5447
  • 卷排序:39
文摘
This study provides a bulk, retrospective analysis of 151 breast and chest wall radiotherapy treatment plans, as a small-scale demonstration of the potential breadth and value of the information that may be obtained from clinical data mining. The treatments were planned at three centres belonging to one organisation over a period of 3 months. All 151 plans were used to evaluate inter-centre consistency and compliance with a local planning protocol. A subset of 79 plans, from one centre, were used in a more detailed evaluation of the effects of anatomical asymmetry on heart and lung dose, the effects of a metallic temporary tissue expander port on dose homogeneity and the overall conformity and homogeneity achieved in routine breast treatment planning. Differences in anatomical structure contouring and nomenclature were identified between the three centres, with all centres showing some non-compliance with the local planning protocol. When evaluated against standard conformity indices, these breast plans performed relatively poorly. However, when evaluated against recommended organ-at-risk tolerances, all evaluated plans performed sufficiently well that tighter planning tolerances could be recommended for future planning. Heart doses calculated in left breast and chest wall treatments were significantly higher than heart doses calculated in right sided breast and chest wall treatments (p < 0.001). In the treatment involving a temporary tissue expander, the inflated implant effectively pushed the targeted breast tissue away from the healthy tissues, leading to a dose distribution that was relatively conformal, although attenuation through the tissue expander’s metallic port may have been underestimated by the treatment planning system. The results of this study exemplify the use of bulk treatment planning data to evaluate clinical workloads and inform ongoing treatment planning.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700