用户名: 密码: 验证码:
Design and commissioning of a timestamp-based data acquisition system for the DRAGON recoil mass separator
详细信息    查看全文
  • 作者:G. Christian (1)
    C. Akers (1) (2)
    D. Connolly (3)
    J. Fallis (1)
    D. Hutcheon (1)
    K. Olchanski (1)
    C. Ruiz (1)
  • 刊名:The European Physical Journal A - Hadrons and Nuclei
  • 出版年:2014
  • 出版时间:April 2014
  • 年:2014
  • 卷:50
  • 期:4
  • 全文大小:1,031 KB
  • 参考文献:1. C. Akers / et al., Phys. Rev. Lett. 110, 262502 (2013). CrossRef
    2. A.L. Sallaska, C. Wrede, A. García, D.W. Storm, T.A.D. Brown, C. Ruiz, K.A. Snover, D.F. Ottewell, L. Buchmann, C. Vockenhuber, D.A. Hutcheon, J.A. Caggiano, Phys. Rev. Lett. 105, 152501 (2010). CrossRef
    3. L. Erikson / et al., Phys. Rev. C 81, 045808 (2010). CrossRef
    4. C. Ruiz / et al., Phys. Rev. Lett. 96, 252501 (2006). CrossRef
    5. S. Bishop / et al., Phys. Rev. Lett. 90, 162501 (2003). CrossRef
    6. J. Fallis / et al., Phys. Rev. C 88, 045801 (2013). CrossRef
    7. C. Vockenhuber / et al., Phys. Rev. C 76, 035801 (2007). CrossRef
    8. J.M. D'Auria / et al., Phys. Rev. C 69, 065803 (2004). CrossRef
    9. B. Davids, R.H. Cyburt, J. José, S. Mythili, Astrophys. J. 735, 40 (2011). CrossRef
    10. C. Matei / et al., Phys. Rev. Lett. 97, 242503 (2006). CrossRef
    11. D. Schürmann, A.D. Leva, L. Gialanella, R. Kunz, F. Strieder, N.D. Cesare, M.D. Cesare, A. D'Onofrio, K. Fortak, G. Imbriani, D. Rogalla, M. Romano, F. Terrasi, Phys. Lett. B 703, 557 (2011). CrossRef
    12. D. Hutcheon / et al., Nucl. Instrum. Methods Phys. Res. A 498, 190 (2003). CrossRef
    13. R. Laxdal, Nucl. Instrum. Methods Phys. Res. B 204, 400 (2003). CrossRef
    14. C. Vockenhuber, L. Erikson, L. Buchmann, U. Greife, U. Hager, D. Hutcheon, M. Lamey, P. Machule, D. Ottewell, C. Ruiz, G. Ruprecht, Nucl. Instrum. Methods Phys. Res. A 603, 372 (2009). CrossRef
    15. C. Wrede, A. Hussein, J.G. Rogers, J. D'Auria, Nucl. Instrum. Methods Phys. Res. B 204, 619 (2003). CrossRef
    16. A. Simon, J. Fallis, A. Spyrou, A.M. Laird, C. Ruiz, L. Buchmann, B.R. Fulton, D. Hutcheon, L. Martin, D. Ottewell, A. Rojas, Eur. Phys. J. A 49, 1 (2013). CrossRef
    17. K. Olchanski, VME-NIMIO32 - General Purpose VME FPGA Board, Tech. Rep. (TRIUMF, Vancouver, BC Canada, 2012).
    18. Cyclone Device Handbook, Tech. Rep. (Altera Corporation, San Jose, CA USA, 2008).
    19. Model V1190-VX1190 A/B, 128/64 Channel Multihit TDC, Tech. Rep. (CAEN S.p.A., Viareggio, Italy, 2012).
    20. Model V792/V792N, 32/16 Channel QDC, Tech. Rep. (CAEN S.p.A., Viareggio, Italy, 2010).
    21. Model V812 16 Channel Constant Fraction Discriminator, Tech. Rep. (CAEN S.p.A., Viareggio, Italy, 2011).
    22. Model V785, 16/32 Channel Peak Sensing ADC, Tech. Rep. (CAEN S.p.A., Viareggio, Italy, 2012).
    23. S. Ritt, P. Amaudruz, in Proceedings of the Xth IEEE REAL TIME Conference (1997) pp. 309--312, see also http://midas.psi.ch.
    24. Daq related information site, http://daq-plone.triumf.ca/ (2012) accessed: 2013-11-25.
    25. R. Brun, F. Rademakers, Nucl. Instrum. Methods Phys. Res. A 389, 81 (1997) see also http://root.cern.ch. CrossRef
    26. DRAGON analysis codes (2014) https://github.com/dragontriumf/analyzer/ accessed: 2014-02-20.
    27. N.M. Josuttis, The C++ Standard Library: A Tutorial and Reference, 2nd edition (Addison Wesley Longman, USA, 2012). .
    28. J. Maddock, Boost TR1, http://www.boost.org/doc/libs/1_55_0/doc/html/boost_tr1.html (2005) accessed: 2013-11-25.
    29. G. Christian, D. Hutcheon, C. Akers, D. Connolly, J. Fallis, C. Ruiz, Phys. Rev. C 88, 038801 (2013). CrossRef
    30. S. Engel / et al., Nucl. Instrum. Methods Phys. Res. A 553, 491 (2005). CrossRef
    31. S. Engel, Awakening of the DRAGON: Commissioning of the DRAGON recoil separator facility and first studies on the 21Na( / α, p)22Mg reaction, PhD thesis, Ruhr-Universit?t Bochum, Bochum, Germany (2003) unpublished.
    32. C. Rolfs, W. Rodne, M. Shapiro, H. Winkler, Nucl. Phys. A 241, 460 (1975). CrossRef
    33. J. José, A. Coc, M. Hernanz, Astrophys. J 520, 347 (1999). CrossRef
    34. N. Prantzos, A. Coc, J.P. Thibaud, Astrophys. J 379, 729 (1991). CrossRef
    35. R. Bloch, T. Knellwolf, R. Pixley, Nucl. Phys. A 123, 129 (1969). CrossRef
    36. C. Iliadis, R. Longland, A. Champagne, A. Coc, R. Fitzgerald, Nucl. Phys. A 841, 31 (2010). CrossRef
    37. G.C. Thomas, N.W. Tanner, Proc. Phys. Soc. 75, 498 (1960). CrossRef
    38. J. Keinonen, M. Riihonen, A. Anttila, Phys. Rev. C 15, 579 (1977). CrossRef
    39. D.G. Gigliotti, Efficiency calibration measurement and geant simulation of the DRAGON BGO gamma ray array at TRIUMF, Master's thesis, University of Northern British Columbia, Prince George, Canada (2004) unpublished.
    40. R. Firestone, Nucl. Data Sheets 103, 269 (2004). CrossRef
    41. K. Jayamanna, F. Ames, G. Cojocaru, R. Baartman, P. Bricault, R. Dube, R. Laxdal, M. Marchetto, M. MacDonald, P. Schmor, G. Wight, D. Yuan, Rev. Sci. Instrum. 79, 02C711 (2008).
  • 作者单位:G. Christian (1)
    C. Akers (1) (2)
    D. Connolly (3)
    J. Fallis (1)
    D. Hutcheon (1)
    K. Olchanski (1)
    C. Ruiz (1)

    1. TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
    2. Department of Physics, University of York, Heslington, York, YO10 5DD, UK
    3. Department of Physics, Colorado School of Mines, 1523 Illinois Street, Golden, CO, 80401, USA
  • ISSN:1434-601X
文摘
The DRAGON recoil mass separator at TRIUMF exists to study radiative proton and alpha capture reactions, which are important in a variety of astrophysical scenarios. DRAGON experiments require a data acquisition system that can be triggered on either reaction product (γ-ray or heavy ion), with the additional requirement of being able to promptly recognize coincidence events in an online environment. To this end, we have designed and implemented a new data acquisition system for DRAGON, which consists of two independently triggered readouts. Events from both systems are recorded with timestamps from a 20 MHz clock that are used to tag coincidences in the earliest possible stage of the data analysis. Here we report on the design, implementation, and commissioning of the new DRAGON data acquisition system, including the hardware, trigger logic, coincidence reconstruction algorithm, and live time considerations. We also discuss the results of an experiment commissioning the new system, which measured the strength of the E c.m. = 1113 keV resonance in the 20 Ne(p, γ)21 Na radiative proton capture reaction.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700