用户名: 密码: 验证码:
Electropolymerized Poly(3,4-ethylendioxythiophene)/Graphene Composite Film and its Application in Quantum Dots Electrochemiluminescence Immunoassay
详细信息    查看全文
  • 作者:Weiping Li (1)
    Weijian Dai (1)
    Lei Ge (1)
    Shenguang Ge (1)
    Mei Yan (1)
    Jinghua Yu (1)
  • 关键词:Poly(3 ; 4 ; ethylendioxythiophene)/graphene ; CdTe quantum dots coated carbon nanosphere ; Electrochemiluminescence immunosensor ; Prostate ; specific antigen ; Point ; of care testing
  • 刊名:Journal of Inorganic and Organometallic Polymers and Materials
  • 出版年:2013
  • 出版时间:May 2013
  • 年:2013
  • 卷:23
  • 期:3
  • 页码:719-725
  • 全文大小:548 KB
  • 参考文献:1. D.W. Hatchett, M. Josowicz, Chem. Rev. 108, 746 (2008) CrossRef
    2. S. Cosnier, M. Stoytcheva, A. Senillou, H. Perrot, R.P.M. Furriel, F.A. Leone, Anal. Chem. 71, 3692 (1999) CrossRef
    3. M. Gerard, A. Chaubey, B.D. Malhotra, Biosens. Bioelectron. 17, 345 (2002) CrossRef
    4. J. Ouyang, C.W. Chu, F.C. Chen, Q. Xu, Y. Yang, Adv. Funct. Mater. 15, 203 (2005) CrossRef
    5. G. Heywang, F. Jonas, Adv. Mater. 4, 116 (1992) CrossRef
    6. A. Kros, S.W.F.M. Van-Hovell, N.A.J.M. Sommerdijk, R.J.M. Nolte, Adv. Mater. 13, 1555 (2001) CrossRef
    7. X. Wang, C. Wang, K. Qu, Y. Song, J. Ren, D. Miyoshi, N. Sugimoto, X. Qu, Adv. Funct. Mater. 20, 3967 (2010) CrossRef
    8. Y. Zhang, X.M. Sun, L.Z. Zhu, H.B. Shen, N.Q. Jia, Electrochim. Acta 56, 1239 (2011) CrossRef
    9. J.H. Jung, D.S. Cheon, F. Liu, K.B. Lee, T.S. Seo, Angew. Chem. Int. Ed. 49, 5708 (2010) CrossRef
    10. J.S. Erickson, F.S. Ligler, Nature 456, 178 (2008) CrossRef
    11. A.M. Yates, S.J. Elvin, D.E. Williamson, J. Immunoassay 20, 31 (1999) CrossRef
    12. T. Matsuya, S. Tashiro, N. Hoshino, N. Shibata, Y. Nagasaki, K. Kataoka, Anal. Chem. 75, 6124 (2003) CrossRef
    13. Z.F. Fu, F. Yan, H. Liu, Z.J. Yang, H.X. Ju, Biosens. Bioelectron. 23, 1063 (2008) CrossRef
    14. D. Schmalzing, W. Nashabeh, Electrophoresis 18, 2184-193 (1997) CrossRef
    15. P. Bertoncello, R.J. Forster, Biosens. Bioelectron. 24, 3191 (2009) CrossRef
    16. M.M. Richter, Chem. Rev. 104, 3003 (2004) CrossRef
    17. T. Ala-Kleme, P. Makinen, T. Ylinen, L. Vare, S. Kulmala, P. Ihalainen, J. Peltonen, Anal. Chem. 78, 8288 (2006) CrossRef
    18. X. Liu, H.X. Ju, Anal. Chem. 80, 5377 (2008) CrossRef
    19. D. Du, Z.X. Zou, Y.S. Shin, J. Wang, H. Wu, M.H. Engelhard, J. Liu, I.A. Aksay, Y.H. Lin, Anal. Chem. 82, 2989 (2010) CrossRef
    20. L.R. Kong, X.F. Lu, X.J. Bian, W.J. Zhang, C. Wang, Langmuir 26, 5985 (2010) CrossRef
    21. A. Ambrosi, M.T. Castaneda, A.J. Killard, M.R. Smyth, S. Alegret, A. Merko?i, Anal. Chem. 79, 5232 (2007) CrossRef
    22. G.F. Jie, L.L. Li, C. Chen, J. Xuan, J.J. Zhu, Biosens. Bioelectron. 24, 3352 (2009) CrossRef
    23. Y. Wan, W.P. Deng, Y. Su, X.H. Zhu, C. Peng, H.Y. Hu, H.Z. Peng, S.P. Song, C.H. Fan, Biosens. Bioelectron. 30, 93 (2011) CrossRef
    24. D.A. Healy, C.J. Hayes, P. Leonard, L. McKenna, R. O’Kennedy, Trends Biotechnol. 25, 125 (2007) CrossRef
    25. N. Gaponik, D.V. Talapin, A.L. Rogach, K. Hoppe, E.V. Shevchenko, A. Kornowski, A. Eychmüller, H. Weller, J. Phys. Chem. B 106, 7177 (2002) CrossRef
    26. X.M. Sun, Y.D. Li, Angew. Chem. 116, 607 (2004) CrossRef
    27. W.S. Hummers, R.E. Offeman, J. Am. Chem. Soc. 80, 1339 (1958) CrossRef
    28. G. Frens, Nat. Phy. Sci. 241, 20 (1973)
    29. G.F. Jie, J.J. Zhang, D.C. Wang, C. Cheng, H.Y. Chen, J.J. Zhu, Anal. Chem. 80, 4033 (2008) CrossRef
    30. S.J. Xu, Y. Liu, T.H. Wang, J.H. Li, Anal. Chem. 83, 3817 (2011) CrossRef
    31. B.V. Chikkaveeraiah, A. Bhirde, R. Malhotra, V. Patel, J.S. Gutkind, J.F. Rusling, Anal. Chem. 81, 9129 (2009) CrossRef
    32. B. Acevedo, Y. Perera, M. Ruiz, G. Rojas, J. Benítez, M. Ayala, J. Gavilondo, Clin. Chim. Acta 317, 55 (2002) CrossRef
  • 作者单位:Weiping Li (1)
    Weijian Dai (1)
    Lei Ge (1)
    Shenguang Ge (1)
    Mei Yan (1)
    Jinghua Yu (1)

    1. Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People’s Republic of China
  • ISSN:1574-1451
文摘
Poly(3,4-ethylendioxythiophene) (PEDOT) films have been electrochemically polymerized on graphene (GR) modified glassy carbon electrode (GCE) simply by a one-step cyclic voltammetry (CV) method in an aqueous media in the absence of any surfactant. The PEDOT/GR composite films were characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). This composite film provided an excellent platform for immobilization of antibody with good bioactivity, and conductivity through Au nanoparticles (AuNPs) as a linker. With a sandwich-type immunoassay format, the analyte and then the CdTe quantum dots coated carbon nanosphere (CNS@CdTe)-labeled antibody were successively bound to the immunosensor. The dual-amplification strategy greatly enhanced the sensitivity for point-of-care testing (POCT) of prostate-specific antigen (PSA). Under optimal conditions, the proposed method could detect PSA with a linear range of 0.001-0?ng?mL? and a detection limit down to 0.8?pg?mL?. The assay results of PSA in clinical serum samples from the Tumor Hospital were in acceptable agreement with the reference values from enzyme-linked immunosorbent assay. The proposed ECL immunosensor exhibited high sensitivity and stability, and could be applied in POCT of other tumor markers for remote regions and developing countries.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700