用户名: 密码: 验证码:
Instrumental neutron activation analysis of samples with volumes from 2 to 350 ml
详细信息    查看全文
  • 作者:R. Gwozdz
  • 刊名:Journal of Radioanalytical and Nuclear Chemistry
  • 出版年:2007
  • 出版时间:March, 2007
  • 年:2007
  • 卷:271
  • 期:3
  • 页码:751-759
  • 全文大小:93 KB
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Nuclear Chemistry
    Physical Chemistry
    Nuclear Physics, Heavy Ions and Hadrons
    Diagnostic Radiology
    Inorganic Chemistry
  • 出版者:Akad茅miai Kiad贸, co-published with Springer Science+Business Media B.V., Formerly Kluwer Academic
  • ISSN:1588-2780
文摘
Usually neutron activation analyses are performed in point-source geometry. However, specially designed irradiation positions and carefully planned measuring conditions enabled the activation and analysis of samples with weights up to several tens of kilograms. A dedicated character of irradiation and of measuring conditions was the main reason for a very limited application of such activation analysis. The use of routine irradiation facilities and standard conditions for analytical gamma-spectrometric measurements is described. Starting with samples of some hundred milligrams usually used in activation, through multi-gram samples to several hundred gram samples, irradiation and measuring conditions were studied and tested for development of the method. This work began in 1991 in Denmark, using the Danish DR-3 reactor. Since then different aspects of the method have been investigated on 6 reactors; in Denmark on DR-3, in Austria on Triga-MkII (in Vienna), and Astra (in Seibersdorf), in the German Federal Republic on FRG-1 in Geesthacht, in Norway on Jeep II (in Kjeller), and in Kazakhstan on VVR-K (in Alatau). Altogether more than 1000 samples have been irradiated and measured. In total, the roughly 30 kg of irradiated materials included almost 300 large samples of more than 30 gram weight. The following theoretical and practical aspects were investigated during the work: theoretical problems concerning neutron self-absorption in common organic and inorganic materials, as well as gamma-attenuation during the measurement. From a more practical point of view: health physics and radiation hazards during irradiation, measurement, transportation and storage of samples with several hundred grams weight. Special requirements to irradiation containers were formulated and various containers were tested. Main advantages and drawbacks of the method are discussed.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700