用户名: 密码: 验证码:
Numerical and experimental studies of injection compression molding process for thick plastic gas valve stem
详细信息    查看全文
文摘
A crucial problem in injection molding of the thick plastic stem that is a key part of high-pressure gas valve is the formation of internal voids, because the structural failure of plastic stem owing to the internal voids not only deteriorates the operating function of gas valve but also may lead to the tremendous loss of financial and human resources. In this context, the goal of this study is to examine whether the formation of internal voids can be successfully suppressed when injection molding is replaced with injection compression molding. To examine this possibility, the major mold flow characteristics between injection molding and injection compression molding are firstly compared through 3-D thermal flow analyses. Next, for the sake of verification of numerical comparison, the plastic stem specimens are manufactured by both molding processes and the internal void formation is inspected using X-ray photos and cutting planes of specimens. Through the comparative numerical and experimental studies, it is confirmed that the crucial formation of internal voids in the conventional injection molding process can be successfully and completely removed by employing the injection compression molding.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700