用户名: 密码: 验证码:
Retention modelling in hydrophilic interaction chromatography
详细信息    查看全文
  • 作者:Melvin R. Euerby ; Jennifer Hulse…
  • 关键词:Hydrophilic interaction chromatography ; Retention behaviour ; Retention and peak width modelling ; Influence of operating parameters ; Method development strategy ; Design of experiments
  • 刊名:Analytical and Bioanalytical Chemistry
  • 出版年:2015
  • 出版时间:December 2015
  • 年:2015
  • 卷:407
  • 期:30
  • 页码:9135-9152
  • 全文大小:1,999 KB
  • 参考文献:1.Buszewski B, Noda S (2012) Anal Bioanal Chem 402:231-47CrossRef
    2.Pontén E (2012) Advancements in the understanding of stationary phases for HILIC http://?www.?chromatographyon?line.?com/?node/-16872 . Accessed 6 July 2015
    3.Majors RE (2013) LCGC Eur 26:505-16
    4.Majors RE (2014) LCGC Eur 27:358-68
    5.Hemstrom P, Irgum K (2006) J Sep Sci 29:1784-821CrossRef
    6.Olsen BA, Pack BW (2013) HILIC a guide for practitioners Wiley & Sons Chemical Analysis A series of monographs on analytical chemistry and its applications Series Editor M F Vitha. Vol 177
    7.Heckendorf A, Krull IS, Rathore A (2013) LCGC N Am 31:998-007
    8.Jandera P, Hajek T, ?ke??ková V, Soukup J (2010) J Sep Sci 33:841-52CrossRef
    9.Jovanovi? M, Raki? T, Jan?i?-Stojanovi? B, Ivanovi? D, Medenica M (2014) Anal Bioanal Chem 406:4217-232CrossRef
    10.Dinh NP, Jonsson T, Irgum K (2011) J Chromatogr A 1218:5880-891CrossRef
    11.Kawachi Y, Ikegami T, Takubo H, Ikegami, Miyamoto YM, Tanaka N (2011) J Chromatogr A 1218:5903-919CrossRef
    12.Wang J, Guo Z, Shen A, Yu L, Xiao Y, Xue X, Zhand X, Liang X (2015) J Chromatogr A 1398:29-6CrossRef
    13.Guo Y, Gaiki S (2005) J Chromatogr A 1074:71-0CrossRef
    14.Chirita RI, West C, Finaru AL, Elfakir C (2010) J Chromatogr A 1217:3091-104CrossRef
    15.Tyteca E, Périat A, Rudaz S, Desmet G, Guillarme D (2014) J Chromatogr A 1337:116-27CrossRef
    16.Périat A, Debrus B, Rudaz S, Guillarme D (2013) J Chromatogr A 1282:72-3CrossRef
    17.Guidelines for HILIC method development (2009) http://?az621941.?vo.?msecnd.?net/?documents/-c98a186-59fb-41be-9dff-1320317b7dde.?pdf . Accessed 6 July 2015
    18.HILIC separations. A practical guide to HILIC mechanisms, method development and troubleshooting (2014) https://?www.?thermoscientific-?com/?content/?dam/?tfs/?ATG/?CMD/?cmd-documents/?bro/?bro/?chrom/?lc/?col/?TG-21003-HILIC-Separations-TG21003-EN.?pdf . Accessed 6 July 2015
    19.Guo Y, Gaiki S (2011) J Chromatogr A 1218:5920-938CrossRef
    20.Kumar K, Heaton JC, McCalley DV (2013) J Chromatogr A 1276:33-6CrossRef
    21.Chirita RI, West C, Zubrzycki S, Finaru AL, Elfakir C (2011) J Chromatogr A 1218:5939-963CrossRef
    22.Neue UD, O’Gara JE, Mendez A (2006) J Chromatogr A 1127:161-74CrossRef
    23.Snyder LR, Dolan JW, Gant JR (1979) J Chromatogr 165:3-0CrossRef
    24.Jandera P, Churcek J, Svoboda L (1979) J Chromatogr 174:35-0CrossRef
    25.Schoenmakers PJ, Billiet HAH, De Galan L (1979) J Chromatogr 185:179-95CrossRef
    26.Chambers TK, Fritz JS (1998) J Chromatogr A 797:139-47CrossRef
    27.Horvath C, Melander W, Molnar I (1977) Anal Chem 49:142-54CrossRef
    28.Jandera P, Janderov M, Churcek J (1978) J Chromatogr 148:79-7CrossRef
    29.Baba Y, Kura G (1991) J Chromatogr A 550:5-4CrossRef
    30.Jandera P, Churcek J (1974) J Chromatogr 91:207-21CrossRef
    31.Snyder LR, Dolan JW (2007) High performance gradient elution—the practical application of the linear-solvent strength model. Wiley, Hoboken, p 362
    32.Jin G, Guo Z, Zhang F, Xue X, Jin Y, Liang X (2008) Talanta 76:522-27CrossRef
    33.Urban J, ?ke?iková V, Jandera P, Kubi?ková R, Pospi?olová M (2009) J Sep Sci 32:2530-543CrossRef
    34.Petersson P, Munch J, Euerby MR, Vazhentsev A, McBrien M, Bhal SK, Kassam K (2007) Chromatogr Today 7:15-8
    35.Galaon T, David V (2011) J Sep Sci 34:1423-428CrossRef
    36.Heberger K, G?rgenyi M, Kowalska T (2002) J Chromatogr A 973:135-42CrossRef
    37.Lundell N (1993) J Chromatogr A 639:97-15CrossRef
    38.Hao Z, Baiming X, Weng N (2008) J Sep Sci 31:1449-464CrossRef
    39.Guo Y, Srinivasan S, Gaiki S (2007) Chromatographia 66:223-29CrossRef
    40.Snyder LR, Dolan JW (2007) High-performance gradient elution: the practical application of the linear-solvent-strength model. Wiley, Hoboken, p 399
    41.Euerby MR, Scannapieco F, Rieger H-J, Molnar I (2006) J Chromatogr A 1121:219-27CrossRef
    42.Jandera P (2006) J Chromatogr A 1126:195-18CrossRef
    43.Stuart JD, Lisi DD, Snyder LR (1989) J Chromatogr A 485:657-72CrossRef
    44.Snyder LR, Dolan JW (2007) High-performance gradient elution: the practical application of the linear-solvent-strength model. Wiley, Hoboken, p 23
    45.Wolcott RG, Dolan JW, Snyder LR (2000) J Chromatogr A 869:3-5CrossRef
    46.Heaton JC, Russell JJ, Underwood T, Boughtflower R, McCalley DV (2014) J Chromatogr A 1347:39-8CrossRef
  • 作者单位:Melvin R. Euerby (1) (2)
    Jennifer Hulse (1)
    Patrik Petersson (3)
    Andrey Vazhentsev (4)
    Karim Kassam (4)

    1. Hichrom Ltd, 1 The Markham Centre, Station Road, Theale, Reading Berkshire, RG7 4PE, UK
    2. Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, 161 Cathedral Street, Glasgow, G40RE, Scotland
    3. Novo Nordisk A/S, Novo Nordisk Park, 2760, M?l?v, Denmark
    4. Advanced Chemistry Development Inc. (ACD/Labs), 8 King Street East, Suite 107, Toronto, M5C 1B5, Canada
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Analytical Chemistry
    Food Science
    Inorganic Chemistry
    Physical Chemistry
    Monitoring, Environmental Analysis and Environmental Ecotoxicology
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1618-2650
文摘
The retention behaviour of acidic, basic and quaternary ammonium salts and polar neutral analytes has been evaluated on acidic, basic and neutral hydrophilic interaction chromatography (HILIC) stationary phases as a function of HILIC operating parameters such as MeCN content, buffer concentration, pH and temperature. Numerous empirical HILIC retention models (existing and newly developed ones) have been assessed for their ability to describe retention as a function of the HILIC operating parameters investigated. Retention models have been incorporated into a commercially available retention modelling programme (i.e. ACD/LC simulator) and their accuracy of retention prediction assessed. The applicability of HILIC modelling using these equations has been demonstrated in the two-dimensional isocratic (i.e. buffer concentration versus MeCN content modelling) and one-dimensional gradient separations for a range of analytes of differing physico-chemical properties on the three stationary phases. The accuracy of retention and peak width prediction was observed to be comparable to that reported in reversed-phase chromatography (RPC) retention modelling. Intriguingly, our results have confirmed that the use of gradient modelling to predict HILIC isocratic conditions and vice versa is not reliable. A relative ranking of the importance of the retention and selectivity of HILIC operating parameters has been determined using statistical approaches. For retention, the order of importance was observed to be organic content-gt;?stationary phase-gt;?temperature?≈?mobile phase pH (i.e. pH 3- which mainly effects the ionization of the analyte)?≈?buffer concentration. For selectivity, the nature of the stationary phase-gt;?mobile phase pH-gt;?buffer concentration-gt;?temperature-gt;?organic content. Keywords Hydrophilic interaction chromatography Retention behaviour Retention and peak width modelling Influence of operating parameters Method development strategy Design of experiments

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700