Study on a Plasma-Jet Triggered Trigatron Switch in a 1.0 MJ-Flashlamp Driven Power System
详细信息    查看全文
  • 作者:Li Chen ; Yizhi Huang ; Pengcheng Wang ; Zhan Liu ; Lanjun Yang…
  • 关键词:Trigatron switch ; Plasma ; jet ; Delay time ; Jitter ; Erosion characteristics
  • 刊名:Journal of Fusion Energy
  • 出版年:2016
  • 出版时间:April 2016
  • 年:2016
  • 卷:35
  • 期:2
  • 页码:240-243
  • 全文大小:749 KB
  • 参考文献:1.E.S. Fulkerson et al., NIF power conditioning system testing at LLNL, in 2001 IEEE Pulsed Power Plasma Science Conference, vol 2 (2001), pp. 1524–1527
    2.M.A. Newton et al., Overview and status of the power conditioning system for the national ignition facility, in 2001 IEEE Pulsed Power Plasma Science conference, vol 1 (2001), pp. 405–408
    3.D.L. Smith, J. Hammon, J.M. Wilson et al., FANTM: first article NIF test module. IEEE Trans. Plasma Sci. 28(5), 1316–1323 (2000)ADS CrossRef
    4.A. Watson, A. Donaldson, K. Ikuta et al., Mechanism of electrode surface damage and material removal in high current discharges. IEEE Trans. Magn. 22(6), 1799–1803 (1986)ADS CrossRef
    5.L. Li et al., Analysis on useful lifetime of high-power closing switch with graphite electrodes. IEEE Trans. Plasma Sci. 39(2), 737–743 (2011)ADS CrossRef
    6.G.A. MesyatS, Pulsed Power (Springer, New York, 2005). ISBN 0-306-48654-7
    7.K. Truman, M. Niehaus, Development of a long life triggered spark gap, in 2006 IEEE 27th Power Modulator Symposium Conference (2006), pp. 467–470
    8.L. Chen et al., Design and performance of a plasma-jet triggered graphite trigatron switch. J. Fusion Energ. 34(5), 949–953 (2015) CrossRef
  • 作者单位:Li Chen (1)
    Yizhi Huang (1)
    Pengcheng Wang (1)
    Zhan Liu (1)
    Lanjun Yang (1)
    Lei Xiao (1)

    1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
  • 刊物类别:Engineering
  • 刊物主题:Nuclear Engineering
  • 出版者:Springer Netherlands
  • ISSN:1572-9591
文摘
In the Pre-ionization lamp-check module of the inertial confinement fusion (ICF) power system, the trigatron switch was widely used for its compact structure and high reliability. A plasma-jet triggered trigatron switch (PTTS) for the PILC module of a 1.0 MJ-flashlamp driven ICF power system was developed and evaluated in this paper. The performance of the PTTS and the erosion characteristics were measured after about 4000 discharge cycles of the lifetime tests. The results showed that the ablation of the polymers tube between trigger pin and graphite electrode had a significant influence on the performance degradation of the PTTS. The delay time increased from 9 to 20 µs and the jitter was less than 1.0 µs under operating voltage of 23.5 kV, the erosion of the graphite electrodes was not serious and a stable self-breakdown voltage was obtained, the degradation of the PTTS was mainly attributed to the ablation of the polymers tube, good performance of the PTTS could be obtained when the polymers tube was renewed.