用户名: 密码: 验证码:
Popular pharmaceutical residues in hospital wastewater: quantification and qualification of degradation products by mass spectroscopy after treatment with membrane bioreactor
详细信息    查看全文
  • 作者:M. Chiarello ; L. Minetto…
  • 刊名:Environmental Science and Pollution Research
  • 出版年:2016
  • 出版时间:August 2016
  • 年:2016
  • 卷:23
  • 期:16
  • 页码:16079-16089
  • 全文大小:825 KB
  • 刊物类别:Earth and Environmental Science
  • 刊物主题:Environment
    Environment
    Atmospheric Protection, Air Quality Control and Air Pollution
    Waste Water Technology, Water Pollution Control, Water Management and Aquatic Pollution
    Industrial Pollution Prevention
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1614-7499
  • 卷排序:23
文摘
The occurrence of drugs in wastewater has been considered an imminent risk to the population, for the treatments used are usually ineffective. The presence of four popular drug residues (metformin, paracetamol, tetracycline, and enalapril) in hospital effluents, by using ultra-fast liquid chromatography tandem mass spectrometry (UFLC-MS/MS) with electrospray (ESI) ionization, and removal/degradation by membrane bioreactor (MBR) system are investigated in this study. For analysis method, all standard calibration curves showed satisfactory linearity (R2 ≥ 0.993) within a relatively wide range. The recovery was between 70.4 and 105.0 %, and the relative standard deviation (RSD) values were within the ranges of 8.2 and 13.5 %. The effluent samples were collected at the end of the process treated in a bench-scale MBR treatment system and preconcentrated on solid-phase extraction (SPE) cartridges. Following that procedure, the chemical analysis demonstrated that the MBR system was effective in enalapril 94.3 ± 7.63 %, tetracycline 99.4 ± 0.02 %, and paracetamol 98.8 ± 0.86 % removal. However, the polar metformin was less effectively removed (35.4 ± 12.49 %). Moreover, the degradation products were investigated using high-resolution mass spectrometry (HRMS) by quadrupole–time of flight (Q-TOF), which has been indicated a tetracycline metabolite. In order to investigate the environmental impact, the wastewater potential risk was evaluated. The risk quotient (RQ) by measure environmental concentration (MEC) and its predicted no effect concentration (PNEC) ratio (RQ = MEC/PNEC) was between 0.003 (enalapril) to 0.815 (paracetamol). Finally, this work demonstrates that UFLC-MS/MS (ESI-Q) is a sensitive and selective method for drug analysis in wastewater and with ESI-Q-TOF has the accuracy required for determining the degradation products of these compounds. Also, it indicated that membrane bioreactor systems represent a new generation of processes that have proved to outperform conventional treatment showing better effluent quality. The removal capacity studied in this work demonstrates the efficiency of this process.KeywordsPharmaceutical residuesDegradation productMass spectrometryHospital effluentMembrane bioreactor

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700