用户名: 密码: 验证码:
Femoral rotation influences dynamic alignment of the lower extremity in total knee arthroplasty
详细信息    查看全文
  • 作者:Zhongyuan Zhao ; Weiguang Wang ; Shijun Wang ; Limin Jiang…
  • 关键词:Total knee arthroplasty ; Dynamic alignment ; Computer navigation
  • 刊名:International Orthopaedics
  • 出版年:2015
  • 出版时间:January 2015
  • 年:2015
  • 卷:39
  • 期:1
  • 页码:55-60
  • 全文大小:687 KB
  • 参考文献:1. Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop 232:168-73
    2. Jeffrey RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg 73:709-14
    3. B?this H, Perlick L, Tingart M (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg 86:682-87 CrossRef
    4. Jenny JY, Boeri C (2001) Implantation d’une prothèse totale de genou assistée par ordinateur. Rev Chir Orthop 87:645-52
    5. Sparmann M, Wolke B, Czupalla H (2003) Positioning of total knee arthroplasty with and without navigation sup-port. A prospective randomised study. J Bone Joint Surg 85:830-35
    6. Stindel E, Briard JL, Merloz P (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7:156-68 CrossRef
    7. Zorman D, Etuin P, Jennart H (2005) Computer-assisted total knee arthroplasty: comparative results in a preliminary series of 72 cases. Acta Orthop Belg 71:696-02
    8. Daniilidis K, Tibesku CO (2013) Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop 37:45-0. doi:10.1007/s00264-012-1732-1. Epub 2012 Dec 12 CrossRef
    9. Picard F, Gregori A, Dean F et al (2006) Computer-assisted dynamic total knee arthroplasty using Whiteside’s line for alignment. Orthopedics 29:104-
    10. Anouchi YS, Whiteside LA, Kaiser AD et al (1993) The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop 287:170
    11. Clayton ML, Thirupathi R (1982) Patellar complica-tions after total condylar arthroplasty. Clin Orthop Relat Res 170:152-55
    12. Nagamine R, White SE, McCarthy DS et al (1995) Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty. J Arthroplasty 10:265-0 CrossRef
    13. Engh GA (2000) Orienting the femoral component at total knee arthroplasty. Am J Knee Surg 13:162-65
    14. Mayr HO, Reinhold M, Hube R et al (2014) Rotational laxity and collateral ligament laxity following total knee arthroplasty with rotating platform. Int Orthop 38:1379-6. doi:10.1007/s00264-014-2308-z. Epub 2014 Mar 7
    15. Olcott CW, Scott RD (2000) A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplasty 15:22- CrossRef
    16. Jerosch J, Peuker E, Philipps B et al (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepi-condylar axis. Knee Surg Sports Traumatol Arthrosc 10:194-97 CrossRef
    17. Jenny JY, Boeri C (2004) Low reproducibility of the intra-operative measurement of the tran-sepicondylar axis during total knee replacement. Acta Orthop Scand 75:74-7 CrossRef
    18. Galaud B, Beaufils P, Michaut M et al (2008) Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases. Rev Chir Orthop Reparatrice Appar Mot 94:573- CrossRef
    19. Fulkerson JP, Schutzer SF, Ramsby GR (1987) Computerized tomography of the patellofemoral joint before and after lateral release or realignment. Arthrosc 3:19-4 CrossRef
    20. Aglietti P, Insall JN, Cerulli G (1983) Patellar pain and incongruence: I. Measurements of incongruence. Clin Orthop Relat Res 176:217-24
    21. Boisgard S, Moreau PE, Descamps S (2003) Computed tomographic study of the posterior condylar angle in arthritic knees: its use in the rotational positioning of the femoral implant of total knee prostheses. Surg Radiol Anat 2
  • 刊物类别:Medicine
  • 刊物主题:Medicine & Public Health
    Orthopedics
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-5195
文摘
Purpose Besides the long-leg standing X-ray film focusing on static standing mechanical alignment of the lower extremity, dynamic alignment from full extension to 90° flexion after total knee arthroplasty (TKA) is rarely mentioned. Computer-assisted surgical technology enables surgeons to measure and assess knee behaviour during surgery. This study was designed to analyse the influences of femoral rotation on dynamic alignment of the lower extremity in TKA. Methods Seventy-six consecutive patients with end-stage knee osteoarthritis were enrolled. External rotation osteotomy of the distal femur during TKA was completed according to the pre-operative external rotation angle (ERA), intra-operative transepicondylar axis (TEA) and anteroposterior (AP) line. Passive dynamic alignment of the lower extremity during knee flexion was recorded. The variation trend of hip–knee–ankle (HKA) alignment and the influences of femoral external rotation osteotomy were analysed. Results Postoperative deviation of HKA alignment from 0° to 90° flexion was associated with the rotational alignment of the femoral component (r-??0.769, p--.001). Variation trend of HKA alignment during knee flexion tended to be varus, valgus and neutral according to the selected angle of external rotation osteotomy of the distal femur. Conclusion External rotation osteotomy of the distal femur played a crucial role in determining dynamic HKA alignment in TKA.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700