用户名: 密码: 验证码:
Computer-assisted three-dimensional correlation between the femoral neck-shaft angle and the optimal entry point for antegrade nailing
详细信息    查看全文
文摘
Optimal entry point for antegrade femoral intramedullary nailing (IMN) remains controversial in the current medical literature. The definition of an ideal entry point for femoral IMN would implicate a tenseless introduction of the implant into the canal with anatomical alignment of the bone fragments. This study was undertaken in order to investigate possible existing relationships between the true 3D geometric parameters of the femur and the location of the optimum entry point. A sample population of 22 cadaveric femurs was used (mean age = 51.09 ± 14.82 years). Computed-tomography sections every 0.5 mm for the entire length of femurs were produced. These sections were subsequently reconstructed to generate solid computer models of the external anatomy and medullary canal of each femur. Solid models of all femurs were subjected to a series of geometrical manipulations and computations using standard computer-aided-design tools. In the sagittal plane, the optimum entry point always lied a few millimeters behind the femoral neck axis (mean = 3.5 ± 1.5 mm). In the coronal plane the optimum entry point lied at a location dependent on the femoral neck-shaft angle. Linear regression on the data showed that the optimal entry point is clearly correlated to the true 3D femoral neck-shaft angle (R2 = 0.7310) and the projected femoral neck-shaft angle (R2 = 0.6289). Anatomical parameters of the proximal femur, such as the varus-valgus angulation, are key factors in the determination of optimal entry point for nailing. The clinical relevance of the results is that in varus hips (neck-shaft angle ≤120°) the correct entry point should be positioned over the trochanter tip and the use stiff nails is advised. In cases of hips with neck-shaft angle between 120° and 130°, the optimal entry point lies just medially to the trochanter tip (at the piriformis fossa) and the use of stiff implants is safe. In hips with neck-shaft angle over 130° the anatomical axis of the canal is medially to the base of the neck, in a “restricted area”. In these cases the entry point should be located at the insertion of the piriformis muscle and the application of more malleable implants that could easily follow the medullary canal should be considered.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700