用户名: 密码: 验证码:
Prediction of Postoperative Intraocular Lens Position with Angle-to-Angle Depth Using Anterior Segment Optical Coherence Tomography
详细信息    查看全文
文摘
To evaluate the accuracy of a new formula for predicting postoperative anterior chamber depth (ACD) with preoperative angle-to-angle (ATA) depth using anterior segment (AS) optical coherence tomography (OCT) and to compare it with established methods.

Design

Retrospective consecutive case series.

Participants

Three hundred four eyes (276 patients) implanted with acrylic intraocular lenses (IOLs) were divided randomly into a training set (152 eyes) and a validation set (152 eyes).

Methods

Based on the training set data, the postoperative ACD measured 1 month after surgery was analyzed via multiple linear regression analysis with 5 preoperatively measured variables: ATA depth, ATA width, preoperative ACD measured with AS OCT, axial length (AL), and corneal power. A new regression formula for predicting postoperative ACD was developed using the results of the stepwise analysis. In the validation set data, the coefficients of determination (R2) between the measured postoperative ACD and the predicted postoperative ACD obtained using the new formula were compared with those obtained using the Sanders-Retzlaff-Kraff theoretic (SRK/T) and Haigis formulas. The absolute prediction errors were compared with each formula.

Main Outcome Measures

Postoperative ACD, median absolute prediction error of postoperative ACD, and ocular biometric parameters.

Results

In the training set, ATA depth yielded the highest standard partial regression coefficient value, indicating that ATA depth is the most effective parameter for predicting postoperative ACD. The new regression formula was developed with 3 variables; ATA depth, preoperative ACD, and AL. In the validation set, the postoperative ACDs of the new formula, the SRK/T formula, and Haigis formula were predicted with R2 of 0.71, 0.36, and 0.55, respectively, and the medians of the absolute prediction errors were 0.10 mm, 0.65 mm, and 0.30 mm, respectively. The absolute prediction error with the new formula was significantly smaller than those obtained with the SRK/T and Haigis formulas (P < 0.0001).

Conclusions

The new formula with 3 preoperative parameters—ATA depth, preoperative ACD, and AL—predicted postoperative ACD more accurately than the SRK/T and Haigis formulas. It may be possible to improve the accuracy of IOL power calculation using an improved postoperative ACD prediction with the ATA depth measured by AS OCT.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700