用户名: 密码: 验证码:
Psychometric properties of the 30-m walking test in patients with degenerative cervical myelopathy: results from two prospective multicenter cohort studies
详细信息    查看全文
文摘
The timed 30-m walking test (30MWT) is used in clinical practice and in research to objectively quantify gait impairment. The psychometric properties of 30MWT have not yet been rigorously evaluated.PurposeThis study aimed to determine test-retest reliability, divergent and convergent validity, and responsiveness to change of the 30MWT in patients with degenerative cervical myelopathy (DCM).Study Design/SettingA retrospective observational study was carried out.Patient SampleThe sample consisted of patients with symptomatic DCM enrolled in the AOSpine North America or AOSpine International cervical spondylotic myelopathy studies at 26 sites.Outcome MeasuresModified Japanese Orthopaedic Association scale (mJOA), Nurick scale, 30MWT, Neck Disability Index (NDI), and Short-Form-36 (SF-36v2) physical component score (PCS) and mental component score (MCS) were the outcome measures.MethodsData from two prospective multicenter cohort myelopathy studies were merged. Each patient was evaluated at baseline and 6 months postoperatively.ResultsOf 757 total patients, 682 (90.09%) attempted to perform the 30MWT at baseline. Of these 682 patients, 602 (88.12%) performed the 30MWT at baseline. One patient was excluded, leaving601 in the analysis. At baseline, 81 of 682 (11.88%) patients were unable to perform the test, and their mJOA, NDI, and SF-36v2 PCS scores were lower compared with those who performed the test at baseline. In patients who performed the 30MWT at baseline, there was very high correlation among the three baseline 30MWT measurements (r=0.9569–0.9919). The 30MWT demonstrated good convergent and divergent validity. It was moderately correlated with the Nurick (r=0.4932), mJOA (r=−0.4424), and SF-36v2 PCS (r=−0.3537) (convergent validity) and poorly correlated with the NDI (r=0.2107) and SF-36v2 MCS (r=−0.1984) (divergent validity). Overall, the 30MWT was not responsive to change (standardized response mean [SRM]=0.30). However, for patients who had a baseline time above the median value of 29 seconds, the SRM was 0.45.ConclusionsThe 30MWT shows high test-retest reliability and good divergent and convergent validity. It is responsive to change only in patients with more severe myelopathy. The 30MWT is a simple, quick, and affordable test, and should be used as an ancillary test to evaluate gait parameters in patients with DCM.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700