用户名: 密码: 验证码:
Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces
详细信息    查看全文
文摘
A novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (dpa50) of 4 渭m and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 渭m in the inner diameter) and a rotating, silicone oil-coated Teflon filter substrate at 1 rpm to achieve a uniform particle deposition and avoid solid particle bounce. A final filter is used after the impactor to collect the NPs. Calibration results show that the dpa50 of the respirable cyclone and the micro-orifice impactor are 3.92 卤 0.22 渭m and 101.4 卤 0.1 nm, respectively. The dpa50 at the loaded micro-Al2O3 mass of 0.36鈥?.18 mg is shifted to 102.9鈥?01.2 nm, respectively, while it is shifted to 98.9鈥?7.8 nm at the loaded nano-TiO2 mass of 0.92鈥?.78 mg, respectively. That is, the shift of dpa50 due to solid particle loading is small if the PENS is not overloaded.
Both NPs and RPM concentrations were found to agree well with those of the IOSH respirable cyclone and MOUDI. By using the present PENS, the collected samples can be further analyzed for chemical species concentrations besides gravimetric analysis to determine the actual exposure concentrations of ENMs in both RPM and NPs fractions in workplaces, which are often influenced by the background or incident pollution sources.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700