Dual- versus single-coil implantable defibrillator leads: review of the literature
详细信息    查看全文
  • 作者:J?rg Neuzner (1)
    J?rg Carlsson (2)
  • 关键词:Implantable cardioverter/defibrillator ; Lead ; Dual coil ; Single coil ; Lead extraction ; Defibrillation threshold
  • 刊名:Clinical Research in Cardiology
  • 出版年:2012
  • 出版时间:April 2012
  • 年:2012
  • 卷:101
  • 期:4
  • 页码:239-245
  • 全文大小:195KB
  • 参考文献:1. Gradaus R, Breithardt G, B?cker D (2002) ICD leads: design and chronic dysfunctions. Pacing Clin Electrophysiol 26:649-57 CrossRef
    2. Haqqani HM, Mond HG (2009) The implantable cardioverter–defibrillator lead: principles, progress, and promises. Pacing Clin Electrophysiol 32:1336-353 CrossRef
    3. Maisel WH (2007) Transvenous implantable cardioverter–defibrillator leads. The weakest link. Circulation 115:2461-463 CrossRef
    4. Maisel WH, Kramer DB (2008) Implantable cardioverter–defibrillator lead performance. Circulation 117(2721):2723
    5. Eckstein J, Koller MT, Zabel M, Kalusche D, Schaer BA, Osswald S, Sticherling C (2008) Necessity for surgical revision of defibrillator leads implanted long-term. Causes and management. Circulation 117:2727-733 CrossRef
    6. Hauck M, Bauer A, Voss F, Weretka S, Katus HA, Becker R (2009) “Home monitoring-for early detection of implantable cardioverter–defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98:19-4 CrossRef
    7. Kleemann T, Becker T, Doenges K, Vater M, Senges J, Schneider S, Saggau W, Weisse U, Seidl K (2007) Annual rate of transvenous defibrillation lead defects in implantable cardioverter–defibrillators over a period of >10?years. Circulation 115:2474-480 CrossRef
    8. Boriani G, Biffi M, Marziali A, Diemberger I, Martignani C (2009) A changing scenario in the clinical use of implantable defibrillators: the need for long-term data on lead performance. Europace 11:1- CrossRef
    9. Goette A, Cantu F, van Erven L, Geelen P, Halimi F, Merino JL, Morgan JM et al (2009) Performance and survival of transvenous defibrillation leads: need for a European data registry. Europace 11:31-4 CrossRef
    10. Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA, Freedman RA, Gettes LS et al (2008) ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities. J Am Coll Cardiol 21:e1–e62 CrossRef
    11. Hauser RG, Hayes DL (2009) Increasing hazard of Sprint Fidelis implantable cardioverter–defibrillator lead failure. Heart Rhythm 6:605-10 CrossRef
    12. Ellis CR, Rottman JN (2009) Increased rate of subacute lead complications with small-caliber implantable cardioverter–defibrillator leads. Heart Rhythm 6:619-24 CrossRef
    13. 2010 Product performance reports. Boston Scientific, Inc.; Medtronic, Inc.; St. Jude Medical, Inc
    14. Gadler F (2009) Swedish pacemaker registry 2009. Available at http://www.pacemakerregistret.se/icdpmr/annualReport/2009/annualReport_2009_1.pdf
    15. Bardy GH, Johnson G, Poole JE, Dolack L, Kudenchuk PJ, Kelso D, Mitchel R, Mehra R, Hofer B (1993) A simplified, single-lead unipolar transvenous cardioversion–defibrillation system. Circulation 88:543-47
    16. Bardy GH, Yee R, Jung W (1996) Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators. J Am Coll Cardiol 28:400-10 CrossRef
    17. Knuefermann P, Wolpert C, Spehl S, Korte T, Manz M, Lüderitz B, Jung W (2000) Implantable cardioverter/defibrillator: long-term stability of the defibrillation threshold with a unipolar electrode configuration (active can). Z Kardiol 89:774-80 CrossRef
    18. Poole JE, Bardy GH, Kudenchuk PJ, Dolack GL, Raitt MH, Mehra R, Johnson G (1995) Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system. Pacing Clin Electrophysiol 18:1369-373 CrossRef
    19. Gold MR, Foster AH, Shorofsky SR (1997) Lead system optimization for transvenous defibrillation. Am J Cardiol 80:1163-167 CrossRef
    20. Gold MR, Olsovsky MR, Pelini MA, Peters RW, Shorofsky SR (1998) Comparison of single- and dual-coil active pectoral defibrillation lead systems. J Am Coll Cardiol 31:1391-394 CrossRef
    21. Gold MR, Olsovsky MR, DeGroot PJ, Cuello C, Shorofsky SR (2000) Optimization of transvenous coil position for active can defibrillation thresholds. J Cardiovasc Electrophysiol 11:25-9 CrossRef
    22. Lubinski A, Lewicka-Nowak E, Zienciuk A, Krolak T, Kempa M, Pazdyga A, Raczak C, Swiatecka G (2005) Comparison of defibrillation efficacy using implantable cardioverter–defibrillator with single- or dual-coil defibrillation leads and active can. Kardiol Pol 63:234-41
    23. Gold M, Val-Mejias J, Lennan RB, Tummala R, Goyal S, Kluger J et al (2008) Optimization of superior vena cava coil position and usage for transvenous defibrillation. Heart Rhythm 5:394-99 CrossRef
    24. Bardy GH, Dolack L, Kudenchuk PJ, Poole JE, Mehra R, Johnson G (1994) Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation 89:1090-093
    25. Manolis AS, Chiladakis J, Maounis TN, Vassilikos V, Cokkinos DV (2000) Two-coil versus single-coil transvenous cardioverter defibrillator systems: comparative data. Pacing Clin Electrophysiol 23:1999-002 CrossRef
    26. Schulte B, Sperzel J, Carlsson J, Schwarz T, Ehrlich W, Pitschner HF, Neuzner J (2001) Dual-coil versus single-coil active pectoral implantable defibrillator lead systems: defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements. Europace 3:177-80 CrossRef
    27. Rinaldi CA, Simon RDB, Geelen P, Reek P, Baszko A, Kuehl M, Gill JS (2003) A randomized prospective study of single-coil versus dual-coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy. Pacing Clin Electrophysiol 26:1684-690 CrossRef
    28. Rüb N, Schweitzer O, Mewis C, Kettering K, Kuehlkamp V (2004) Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds. Pacing Clin Electrophysiol 27:346-51 CrossRef
    29. Carlsson J, Schulte B, Erdogan A, Sperzel J, Güttler N, Schwarz T, Pitschner HF, Neuzner J (2003) Prospective randomized comparison of two defibrillation safety margins in unipolar, active pectoral defibrillation therapy. Pacing Clin Electrophysiol 26:613-18 CrossRef
    30. Gold MR, Higgins S, Klein R, Gilliam R, Kopelman H, Hessen S, Payne J, Strickberger SA, Breiter D, Hahn S (2002) Efficacy and temporal stability of reduced safety margins for ventricular defibrillation. Primary results from the Low Energy Safety Study (LESS). Circulation 105:2043-048 CrossRef
    31. Val-Mejias JE, Oza A (2010) Does defibrillation threshold increase as left ventricular ejection fraction decreases? Europace 12:385-88 CrossRef
    32. Morgan JM, Marinskis G (2011) Defibrillation testing at the time of implantable cardioverter defibrillator implantation: results of the European Heart Rhythm Association survey. Europace 13:581-82 CrossRef
    33. Brigniole M, Raciti G, Bongiorni MG, Da Martine G, Favale S, Gasparini M, Luise R, Ochetta E, Prolemer A (2007) Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: a nation-wide survey. Europace 9:540-43 CrossRef
    34. Healey JS, Dorian P, Mitchell LB, Talajic M, Philioppon F, Simpson C, Yee R, Morillo CA, Lamy A, Basta M, Birnie DH, Wang X, Nair GM, Crystal E, Kerr CR, Connolly SJ (1010) Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing. J Cardiovasc Electrophysiol 2:177-82
    35. Swerdlow CD, Russo AM, Degroot PJ (2007) The dilemma of ICD implant testing. Pace Clin Electrophysiol 30:675-00 CrossRef
    36. Shockless Implant Evaluation “SIPMLE-Study; Clinical Trials.gov Identifier: NCT00800384
    37. Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM, Dixit S, Verdino RJ, Nayak HM, Callans DJ, Patel V, Marchlinski FE (2005) Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter–defibrillator insertion? Heart Rhythm 5:456-61 CrossRef
    38. Varma N, Efimov I (2008) Right pectoral implantable cardioverter defibrillators: role of the proximal (SVC) coil. Pacing Clin Electrophysiol 31:1025-035 CrossRef
    39. Epstein AE, Kay N, Plumb VJ, Voshage-Stahl L, Hull ML, for the Endotak investigators (1995) Elevated defibrillation thresholds when right sided venous access is used for nonthoracotomy implantable defibrillator lead implantation. J Cardiovasc Electrophysiol 6:979-86 CrossRef
    40. Friedman PA, Rasmussen MJ, Grice S, Trusty J, Glikson M, Stanton MS (1999) Defibrillation thresholds are increased by right-sided implantation of totally transvenous implantable cardioverter defibrillators. Pacing Clin Electrophysiol 22:1186-192 CrossRef
    41. Gold MR, Shih HT, Herre J, Breiter D, Zhang Y, Schwarz M, for the Low Energy Safety Study Investigators (2007) Comparison of defibrillation efficacy and survival associated with right versus left pectoral placement for implantable defibrillators. Am J Cardiol 100:243-46 CrossRef
    42. Flaker GC, Tummala R, Wilson J (1998) Comparison of right- and left-sided pectoral implantation parameters with the Jewel Active Can cardiodefibrillator. The World Wide Jewel Investigators. Pacing Clin Electrophysiol 21:447-51 CrossRef
    43. Natale A, Sra J, Geiger MJ, Newby K, Akhtar M, Pacifico A (1997) Right side implant of the unipolar single lead defibrillation system. Pacing Clin Electrophysiol 20:1910-912 CrossRef
    44. Keane D, Aweh N, Hynes B, Sheahan RG, Cripps T, Bashir Y et al (2007) Achieving sufficient safety margins with fixed duration waveforms and the use of multiple time constants. Pacing Clin Electrophysiol 30:596-02 CrossRef
    45. Swerdlow CD, Fan W, Brewer JE (1996) Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms. Circulation 94:2278-284
    46. Irnich W (2010) From defibrillation theory to clinical implications. Pacing Clin Electrophysiol 33:814-25 CrossRef
    47. Kroll MW, Schwab JO (2010) Acieving low defibrillation thresholds at implant: pharmacological influences, RV-coil polarity and position, SVC coil usage and positioning, pulse width settings, and the azygous vein. Fundam Clin Pharmacol 24:561-73 CrossRef
    48. Stajduhar KC, Ott GY, Kron J, McAnulty JH, Oliver RP, Reynolds BT, Adler SW, Halperin BD (1996) Optimal electrode position for transvenous defibrillation: a prospective randomized study. J Am Coll Cardiol 27:90-4 CrossRef
    49. Winter J, Heil JE, Schumann C, Lin Y, Schannwell CM, Michel U, Schipke JD, Schulte HD, Gams E (1998) Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study. Eur J Cardiothorac Surg 14:419-25 CrossRef
    50. Rashaba EJ, Bonner M, Wilson J, Shorofski SR, Peters RW, Gold MR (2003) Distal right ventricular coil position reduces defibrillation thresholds. J Cardiovasc Electrophysiol 14:1036-040 CrossRef
    51. Rashaba EJ, Shorofsky SR, Peters RW, Gold MR (2004) Optimization of atrial defibrillation with dual-coil, active pectoral lead system. J Cardiovasc Electrophysiol 15:790-94 CrossRef
    52. Cooklin M, Olsovsky MR, Brockmann RG, Shorofsky SR, Gold MR (1999) Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways. J Am Coll Cardiol 34:358-62 CrossRef
    53. Rashaba EJ, Shorofski SR, Brown T, Peters RW, Gold MR (2005) Clinical predictors of atrial defrillation thresholds with a dual-coil, active pectoral lead system. Heart Rhythm 2:49-4 CrossRef
    54. Rozmus G, Daubert JP, Huang DT, Rosero S, Hall B, Francis C (2005) Venous thrombosis and stenosis after implantation of pacemakers and defibrillators. J Interv Card Electrophysiol 13:9-9 CrossRef
    55. Lickfett L, Bitzen A, Arepally A, Nasir K, Wolpert C, Jeong KM, Krause W, Schimpf R, Lewalter T, Calcins H, Jung W, Lüderitz B (2004) Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace 6:25-1 CrossRef
    56. Parkash R, Crystal E, Bashir J, Simpson C, Birnie D, Sterns L, Exner D (2010) Complications associated with revision of Sprint Fidelis leads: report from the Canadian Heart Rhythm Society Device Advisory Committee. Circulation 121:2384-387 CrossRef
    57. Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Camillo RG, Crossley GH 3rd et al (2009) Transvenous lead extraction: heart rhythm society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm 6:1085-094 CrossRef
    58. Kennergren C, Bjurman C, Wiklund R, G?bel J (2009) A single-centre experience of over one thousand lead extractions. Europace 11:612-17 CrossRef
    59. Bracke FALE, Meijer A, van Gelder LM (2002) Malfunction of endocardial defibrillator leads and lead extraction: where do they meet? Europace 4:19-4 CrossRef
    60. Malecka B, Kutarski A, Grabowski M (2010) Is the transvenous extraction of cardioverter–defibrillator leads more hazardous than of pacemaker leads. Kardiol Pol 68:884-90
    61. Cooper JM, Stephenson EA, Berul CI, Walsh EP, Epstein LM (2003) Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: implications for implantation and management. J Cardiovasc Electrophysiol 14:344-49 CrossRef
    62. Di Cori A, Bongiorni MG, Zucchelli G, Segreti L, Viani S, Paperini L, Soldati E (2010) Transvenous extraction performance of expanded polytetrafluoroethylene covered ICD leads in comparison to traditional ICD leads in humans. Pacing Clin Electrophysiol 33:1376-381 CrossRef
    63. Smith MC, Love CJ (2008) Extraction of transvenous pacing and ICD leads. Pacing Clin Electrophysiol 31:736-52 CrossRef
    64. Hauser RG, Katsiyiannis WT, Gornick CC, Almquist AK, Kallinen LM (2010) Deaths and cardiovascular injuries due to device-assisted implantable cardioverter–defibrillator and pacemaker lead extraction. Europace 12:395-01 CrossRef
    65. Farooqi FM, Talsania S, Hamid S, Rinaldi CA (2010) Extraction of cardiac rhythm devices: indications, techniques and outcomes for the removal of pacemaker and defibrillator leads. Int J Clin Pract 64:1140-147 CrossRef
    66. Bracke F (2008) Complications and lead extraction in cardiac pacing and defibrillation. Neth Heart J 16(Suppl 1):S28–S31
    67. Kennergren C, Bucknall CA, Butter C, Charles R, Fuhrer J, Grosfeld M et al (2007) Laser-assisted lead extraction: the European experience. Europace 9:651-56 CrossRef
  • 作者单位:J?rg Neuzner (1)
    J?rg Carlsson (2)

    1. Medizinische Klinik II, Klinikum Kassel, M?nchebergstrasse 41-43, 34125, Kassel, Germany
    2. Medicinska Kliniken/Kardiologi, L?nssjukhuset i Kalmar, Kalmar, Sweden
文摘
The preferred use of dual-coil implantable defibrillator lead systems in current implantable defibrillator therapy is likely based on data showing statistically lower defibrillation thresholds with dual-coil defibrillator lead systems. The following review will summarize the clinical data for dual- versus single-coil defibrillator leads in the left and right pectoral implant locations, and will then discuss the clinical implications of single- versus dual-coil usage for atrial defibrillation, venous complications, and the risks associated with lead extraction. It will be noted that there are no comparative clinical studies on the use and outcomes of single- versus dual-coil lead systems in implantable defibrillator therapy over a long-term follow-up. The limited long-term reliability of defibrillator leads is a major concern in implantable defibrillator and cardiac resynchronization therapy. A simpler single-coil defibrillator lead system may improve the long-term performance of implanted leads. Furthermore, the superior vena cava coil is suspected to increase interventional risk in transvenous lead extraction. Therefore, the need for objective data on extractions and complications will be emphasized.