用户名: 密码: 验证码:
Multiple target implementation for a doubly fed induction generator based on direct power control under unbalanced and distorted grid voltage
详细信息    查看全文
  • 作者:Heng Nian ; Yi-peng Song
  • 关键词:Direct power control ; Doubly fed induction generator ; Unbalanced and distorted grid voltage ; Vector proportional and integral resonant regulator ; Parameter deviation ; TM315
  • 刊名:Frontiers of Information Technology & Electronic Engineering
  • 出版年:2015
  • 出版时间:April 2015
  • 年:2015
  • 卷:16
  • 期:4
  • 页码:321-334
  • 全文大小:1,529 KB
  • 参考文献:Cardenas, R., Pena, R., Alepuz, S., et al., 2013. Overview of control systems for the operation of DFIGs in wind energy applications. IEEE Trans. Ind. Electron., 60(7): 2776鈥?798. [doi:10.1109/TIE.2013.2243372]CrossRef
    Hu, J., He, Y., 2009. Reinforced control and operation of DFIG-based wind-power-generation system under unbalanced grid voltage conditions. IEEE Trans. Energy Conv., 24(4):905鈥?15. [doi:10.1109/TEC.2008.2001434]CrossRef MathSciNet
    Hu, J., He, Y., Xu, L., et al., 2009. Improved control of DFIG systems during network unbalance using PI-R current regulators. IEEE Trans. Ind. Electron., 56(2):439鈥?51. [doi:10.1109/TIE.2008.2006952]CrossRef
    Hu, J., Xu, H., He, Y., 2013. Coordinated control of DFIG鈥檚 RSC and GSC under generalized unbalanced and distorted grid voltage conditions. IEEE Trans. Ind. Electron., 60(7):2808鈥?819. [doi:10.1109/TIE.2012.2217718]CrossRef
    Iwanski, G., Koczara, W., 2008. DFIG-based power generation system with UPS function for variable-speed applications. IEEE Trans. Ind. Electron., 55(8):3047鈥?054. [doi:10.1109/TIE.2008.918473]CrossRef
    Jabr, H.M., Kar, N.C., 2007. Effects of main and leakage flux saturation on the transient performances of doubly-fed wind driven induction generator. Electr. Power Syst. Res., 77(8):1019鈥?027. [doi:10.1016/j.epsr.2006.08.034]CrossRef
    Lascu, C., Asiminoaei, L., Boldea, I., et al., 2007. High performance current controller for selective harmonic compensation in active power filters. IEEE Trans. Power Electron., 22(5):1826鈥?835. [doi:10.1109/TPEL.2007.904060]CrossRef
    Lascu, C., Asiminoaei, L., Boldea, I., et al., 2009. Frequency response analysis of current controllers for selective harmonic compensation in active power filters. IEEE Trans. Ind. Electron., 56(2):337鈥?47. [doi:10.1109/TIE.2008.2006953]CrossRef
    Liu, C., Blaabjerg, F., Chen, W., et al., 2012. Stator current harmonic control with resonant controller for doubly fed induction generator. IEEE Trans. Power Electron., 27(7):3207鈥?220. [doi:10.1109/TPEL.2011.2179561]CrossRef
    Luna, A., Lima, F.K.A., Santos, D., et al., 2011. Simplified modeling of a DFIG for transient studies in wind power applications. IEEE Trans. Ind. Electron., 58(1):9鈥?0. [doi:10.1109/TIE.2010.2044131]CrossRef
    Martinez, M.I., Susperregui, A., Tapia, G., et al., 2013. Sliding-mode control of a wind turbine-driven double-fed induction generator under non-ideal grid voltages. IET Renew. Power Gener., 7(4):370鈥?79. [doi:10.1049/iet-rpg.2012.0172]CrossRef
    Nian, H., Song, Y., 2014. Direct power control of doubly fed induction generator under distorted grid voltage. IEEE Trans. Power Electron., 29(2):894鈥?05. [doi:10.1109/TPEL.2013.2258943]CrossRef
    Nian, H., Song, Y., Zhou, P., et al., 2011. Improved direct power control of a wind turbine driven doubly fed induction generator during transient grid voltage unbalance. IEEE Trans. Energy Conv., 26(3):976鈥?86. [doi:10.1109/TEC.2011.2158436]CrossRef
    Pena, R., Cardenas, R., Reyes, E., et al., 2011. Control of doubly fed induction generator via an indirect matrix converter with changing DC voltage. IEEE Trans. Ind. Electron., 58(10):4664鈥?674. [doi:10.1109/TIE.2011.2109334]CrossRef
    Xu, H., Hu, J., He, Y., 2012a. Operation of wind-turbine-driven DFIG systems under distorted grid voltage conditions: analysis and experimental validations. IEEE Trans. Power Electron., 27(5):2354鈥?366. [doi:10.1109/TPEL.2011.2174255]CrossRef
    Xu, H., Hu, J., He, Y., 2012b. Integrated modeling and enhanced control of DFIG under unbalanced and distorted grid voltage conditions. IEEE Trans. Energy Conv., 27(3):725鈥?36. [doi:10.1109/TEC.2012.2199495]CrossRef
    Xu, L., Wang, Y., 2007. Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions. IEEE Trans. Power Syst., 22(1):314鈥?23. [doi:10.1109/TPWRS.2006.889113]CrossRef
    Xu, L., Zhi, D., Williams, B.W., 2009. Predictive current control of doubly fed induction generators. IEEE Trans. Ind. Electron., 56(10):4143鈥?153. [doi:10.1109/TIE.2009.2017552]CrossRef
    Zhou, P., He, Y., Sun, D., 2009. Improved direct power control of a DFIG-based wind turbine during network unbalance. IEEE Trans. Power Electron., 24(11):2465鈥?474. [doi:10.1109/TPEL.2009.2032188]CrossRef
  • 作者单位:Heng Nian (1)
    Yi-peng Song (1)

    1. College of Electrical Engineering, Zhejiang University, Hangzhou, 310027, China
  • 刊物类别:Computer Science, general; Electrical Engineering; Computer Hardware; Computer Systems Organization
  • 刊物主题:Computer Science, general; Electrical Engineering; Computer Hardware; Computer Systems Organization and Communication Networks; Electronics and Microelectronics, Instrumentation; Communications Engine
  • 出版者:Zhejiang University Press
  • ISSN:2095-9230
文摘
This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector PI (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage. Key words Direct power control Doubly fed induction generator Unbalanced and distorted grid voltage Vector proportional and integral resonant regulator Parameter deviation

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700