用户名: 密码: 验证码:
Condition-based switching and replacement policies for a two-unit warm standby redundant system subject to non-instantaneous switchover
详细信息    查看全文
  • 作者:Yunpeng Jiang (1)
    Maoyin Chen (1)
    Donghua Zhou (1)
  • 关键词:Condition ; based maintenance ; Warm standby redundant system ; Non ; instantaneous switchover ; Continuous monitoring ; Gamma process
  • 刊名:Chinese Science Bulletin
  • 出版年:2014
  • 出版时间:November 2014
  • 年:2014
  • 卷:59
  • 期:33
  • 页码:4616-4624
  • 全文大小:762 KB
  • 参考文献:1. Amari SV, Dill G (2010) Redundancy optimization problem with warm-standby redundancy. In: IEEE (ed) Reliability and maintainability symposium (RAMS), 2010 proceedings. Annual reliability and maintainability symposium/international symposium on product quality and integrity, San Jose, January 2010. IEEE, New York, pp 1-
    2. Yun WY, Cha JH (2010) Optimal design of a general warm standby system. Reliab Eng Syst Saf 95:880-86 CrossRef
    3. EL-Sherbeny MS (2010) The optimal system for series systems with mixed standby components. J Qual Maint 16:319-34 CrossRef
    4. Zhang T, Xie M, Horigome M (2006) Availability and reliability of k-out-of-(M+N): G warm standby systems. Reliab Eng Syst Saf 91:381-87 CrossRef
    5. Wang H (2002) A survey of maintenance policies of deteriorating systems. Eur J Oper Res 139:469-89 CrossRef
    6. Jardine AKS, Lin D, Banjevic D (2006) A review on machinery diagnostics and prognostics implementing condition-based maintenance. Mech Syst Signal Process 20:1483-510 CrossRef
    7. Ahmad R, Kamaruddin S (2012) An overview of time-based and condition-based maintenance in industrial application. Comput Ind Eng 63:135-49 CrossRef
    8. Nakagawa T, Osaki S (1976) A summary of optimum preventive maintenance policies for a two-unit standby redundant system. Math Method Oper Res 20:171-87 CrossRef
    9. Lee HS, Srinivasan MM (1994) Optimal replacement policies for systems with multiple standby components. IEEE T Reliab 43:414-22 CrossRef
    10. Dohi T, Osaki S, Kaio N (1996) Optimal planned maintenance with salvage cost for a two-unit standby redundant system. Microelectron Reliab 36:1581-588 CrossRef
    11. Yu H, Yalaoui F, Chatelet ? et al (2007) Optimal design of a maintainable cold-standby system. Reliab Eng Syst Saf 92:85-1 CrossRef
    12. Lam Y (1997) A maintenance model for two-unit redundant system. Microelectron Reliab 37:497-04 CrossRef
    13. Zhang YL, Wang GJ, Ji ZC (2006) Replacement problems for a cold standby repairable system. Int J Syst Sci 37:17-5 CrossRef
    14. Zhang YL, Wang GJ (2007) A deteriorating cold standby repairable system with priority in use. Eur J Oper Res 183:278-95 CrossRef
    15. Leung KNF, Zhang YL, Lai KK (2010) A bivariate optimal replacement policy for a cold standby repairable system with repair priority. Nav Res Logist 57:149-58
    16. Leung KNF, Zhang YL, Lai KK (2011) Analysis for a two-dissimilar-component cold standby repairable system with repair priority. Reliab Eng Syst Saf 96:1542-551 CrossRef
    17. Yuan L, Xu J (2011) An optimal replacement policy for a repairable system based on its repairman having vacations. Reliab Eng Syst Saf 96:868-75 CrossRef
    18. Jia J, Wu S (2009) Optimizing replacement policy for a cold-standby system with waiting repair times. Appl Math Comput 214:133-41 CrossRef
    19. Hsieh CC, Chiu KC (2002) Optimal maintenance policy in a multistate deteriorating standby system. Eur J Oper Res 141:689-98 Donghua Zhou (1)

    1. Department of Automation, Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing, 100084, China
  • ISSN:1861-9541
文摘
This study investigates condition-based switching and replacement policies for a two-unit warm standby redundant system subject to non-instantaneous switchover. The system consists of two identical units: one is operating unit, while the other is standby unit. Two units are under continuous monitoring and degradation described by Gamma processes. Both switching and replacement policies are based on the degradation level of the operating unit. The switching and replacement thresholds are decision variables decided by minimizing the long-run expected cost rate. We first setup the mathematical optimization model and then analyze the global optimal solution of replacement threshold, as well as the existence and uniqueness condition for the local optimal solution of switching threshold (STH). Finally, we find that the optimal replacement threshold is “the bigger the better- but the optimal STH depends on some optimal conditions which can be easily computed. Numerical examples are provided to verify the policies, and the effects of non-instantaneous switchover and cost ratio on optimal STHs are numerically discussed.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700