基于热耗最优的汽轮机冷端耦合滑压优化控制
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Optimal Control of Coupling Sliding Pressure of Steam Turbine Based on Optimal Heat Consumption
  • 作者:罗联锋 ; 熊天洪 ; 华兆军
  • 英文作者:Luo Lianfeng;Xiong Tianhong;Hua Zhaojun;Yunnan Huadian Zhenxiong Power Generation Co.,Ltd.;
  • 关键词:全冷端优化 ; 循泵优化 ; 主蒸汽压力优化 ; 实时运行热耗
  • 英文关键词:full cold end optimization;;pump optimization;;main steam pressure optimization;;real-time running heat consumption
  • 中文刊名:仪器仪表用户
  • 机构:云南华电镇雄发电有限公司;
  • 出版日期:2019-09-09
  • 出版单位:仪器仪表用户
  • 年:2019
  • 期:10
  • 语种:中文;
  • 页:99-103
  • 页数:5
  • CN:12-1334/TH
  • ISSN:1671-1041
  • 分类号:TM621
摘要
汽轮机冷端系统是火电机组的重要辅助系统,其运行状态的好坏直接关系到机组的安全、经济运行。通过分析汽轮机冷端系统的换热机理,建立汽机运行热耗高精度在线实时计算模型、主汽轮机各汽缸及各段抽汽效率计算模型、凝汽器性能监测模型、冷却塔特性监测与效率计算模型、全冷端循环水优化计算模型、汽动给水泵组及循环水泵、凝结水泵等在线效率监测模型,然后在这些数学模型的基础上,设计和开发在线实时计算和运行指导程序,开发出完整的汽机岛运行优化节能系统,系统实现汽轮机本体各汽缸及各段抽汽效率、凝汽器性能监测、循泵优化运行指导、冷却塔性能监测及评价、机组实时热耗计算和机组运行工况下最优主蒸汽压力计算和偏差输出等功能,进而实现对机组热耗最优的汽轮机冷端耦合滑压优化控制,提高了机组运行经济性。
        The cold end system of the steam turbine is an important auxiliary system for the thermal power unit. The operation status of the steam turbine is directly related to the safety and economic operation of the unit. By analyzing the heat transfer mechanism of the cold end system of steam turbine, the high-precision online real-time calculation model of turbine heat consumption, the calculation model of steam exhaust efficiency of each cylinder and each section of the main steam turbine, the performance monitoring model of the condenser, the characteristic monitoring and efficiency calculation of the cooling tower are established. Model, full-cold-end circulating water optimization calculation model, steam-driven feed pump group, circulating water pump, condensate pump and other online efficiency monitoring models, and then based on these mathematical models, design and develop online real-time calculation and operation guidance procedures, develop The complete turbine island operation optimizes the energy-saving system. The system realizes the extraction efficiency of each cylinder and each section of the turbine body, the performance monitoring of the condenser, the optimal operation guidance of the pump, the performance monitoring and evaluation of the cooling tower, the real-time heat consumption calculation of the unit and the unit operation. Under the condition of the optimal calculation of the main steam pressure and the deviation output, the optimal control of the coupled cold-slip pressure of the turbine with the optimal heat consumption of the unit is realized, which improves the economical operation of the unit.
引文
[1]李建平,胡勇,吕海涛,等.基于实时稳态模型的汽轮机冷端系统闭环优化控制[J].汽轮机技术,2017,59(4):299-302.
    [2]邢希东,邢百俊,金日锋.600MW火电机组冷端系统节能优化改造效果[J].能源技术经济.2010(12):53-57.
    [3]赵伟光,刘明远,王丰,等.国产超临界600MW汽轮机冷端优化运行方式的确定[J].东北电力技术,2015(6):1-3,23.
    [4]徐星,黄启龙,戴维葆,等.考虑汽轮机工况变化的凝汽器最佳真空的确定及应用[J].动力工程学报,2015,35(1):70-75.
    [5]王玮,曾德良,杨婷婷,等.基于凝汽器压力估计算法的循环水泵最优运行[J].中国电机工程学报,2010,30(14):7-12.
    [6]马海龙,王运民,张希福,等.电厂凝汽式汽轮机最佳运行背压的确定方法[J].汽轮机技术,2013,55(2):118-120.
    [7]陈佳.凝汽器汽相流动与传热特性的数值模型[D].哈尔滨:哈尔滨工程大学,2008.
    [8]王攀,王泳涛,王宝玉.汽轮机冷端优化运行和最佳背压的研究与应用[J].汽轮机技术,2016,58(1):55-57,60.
    [9]胡发明,席京彬.电厂凝汽器循环水的优化运行[J].云南电力技术,2013,41(5):84-86.
    [10]云南华电镇雄发电有限公司.汽轮机实时动态滑压优化研究项目节能效果验收试验报告[R].